Proline 500 PROFINET
Electrical connection
Hauser
33
10. Plug in the RJ45 connector.
11. Firmly tighten the cable glands.
This concludes the PROFINET connection process.
Connecting the supply voltage and additional inputs/outputs
N
ic
h
t
u
n
te
r
ar
e
ö
ffn
e
n
+
E
ESC
–
10 (0.4)
mm (in)
2.
1.
3.
A0033983
1. Push the cable through the cable entry . To ensure tight sealing, do not remove the
sealing ring from the cable entry.
2. Strip the cable and cable ends. In the case of stranded cables, also fit ferrules.
3. Connect the protective ground.
N
ic
h
t
u
n
te
r
ar
e
ö
ffn
e
n
+
E
ESC
–
22 mm
24 mm
5.
4.
A0033984
4. Connect the cable in accordance with the terminal assignment .
Signal cable terminal assignment:
The device-specific terminal assignment is
documented on an adhesive label in the terminal cover.
Supply voltage terminal assignment:
Adhesive label in the terminal cover or
5. Firmly tighten the cable glands.
This concludes the cable connection process.