background image

Orbisint CPS11D and CPS11

Hauser

11

Dipfit CPA111

• Immersion and installation assembly made of plastic for open and closed vessels

• Product Configurator on the product page: 

www.endress.com/cpa111

Technical Information TI00112C

Dipfit CPA140

• pH/ORP immersion assembly with flange connection for very demanding processes

• Product Configurator on the product page: 

www.endress.com/cpa140

Technical Information TI00178C

Flowfit CPA240

• pH/ORP flow assembly for processes with stringent requirements

• Product Configurator on the product page: 

www.endress.com/cpa240

Technical Information TI00179C

Flowfit CPA250

• Flow assembly for pH/ORP measurement

• Product Configurator on the product page: 

www.endress.com/cpa250

Technical Information TI00041C

Ecofit CPA640

• Set comprising adapter for 120 mm pH/ORP electrodes and sensor cable with TOP68 coupling

• Product Configurator on the product page: 

www.endress.com/cpa640

Technical Information TI00246C

Flexdip CYA112

• Immersion assembly for water and wastewater

• Modular assembly system for sensors in open basins, channels and tanks

• Product Configurator on the product page: 

www.endress.com/cya112

Technical Information TI00432C

Buffer solutions

High-quality buffer solutions from Hauser - CPY20

The secondary buffer solutions have been referenced to primary reference material of the PTB

(German Federal Physico-technical Institute) and to standard reference material of NIST (National

Institute of Standards and Technology) according to DIN 19266 by a DKD (German Calibration

Service) accredited laboratory.

Product Configurator on the product page: 

www.endress.com/cpy20

Measuring cables

CYK10 Memosens data cable

• For digital sensors with Memosens technology

• Product Configurator on the product page: 

www.endress.com/cyk10

Technical Information TI00118C

CPK9

• Terminated measuring cable for connecting analog sensors with TOP68 plug-in head

• Selection in accordance with product structure

For more information and to order, please contact your sales office.

CPK1

For pH/ORP electrodes with GSA plug-in head

Ordering information is available from your sales office or at 

www.endress.com

.

Summary of Contents for Orbisint CPS11

Page 1: ...PTFE ring junction Can be used at pressures up to 17 bar abs 246 psi Process glass also for very alkaline applications BA and BT versions Process glass for applications in media containing hydrofluori...

Page 2: ...tegrated Ag AgCl reference system serves as the required reference electrode The transmitter converts the measured voltage into the corresponding pH value using the Nernst equation Measuring system A...

Page 3: ...operating hours under extreme measuring conditions Once the sensor has been connected the sensor data are transferred automatically to the transmitter and used to calculate the current measured value...

Page 4: ...nce converter are a thing of the past EMC safety is guaranteed by screening measures for the digital transmission of measured values Intrinsically safe electronics mean operation in hazardous areas is...

Page 5: ...ata apply only if installing with Endress Hauser assemblies Make sure to follow the installation instructions in the Operating Instructions of the used assembly 15 15 A B A0024316 2 Electrode installa...

Page 6: ...rotective goggles and suitable gloves Pressure temperature ratings absolute A C 10 12 14 16 18 B 50 100 200 250 275 300 5 0 40 80 120 160 200 246 psi p bar T F 40 0 20 60 80 100 0 4 6 8 2 T C 120 135...

Page 7: ...Ag AgCl reference lead reference 4 Advanced Gel electrolyte 5 Ag AgCl reference lead pH 6 PTFE diaphragm 7 pH glass membrane 8 Temperature sensor NTC30K 3 4 5 6 1 2 7 8 9 12 0 47 120 225 360 4 72 8 8...

Page 8: ...llar 3 Ag AgCl reference lead reference 4 Advanced Gel electrolyte 5 Ag AgCl reference lead pH 6 PTFE diaphragm 7 pH glass membrane 8 Temperature sensor Pt100 Weight 0 1 kg 0 2 lbs Materials Electrode...

Page 9: ...FM Class I Div 2 in conjunction with Liquiline M CM42 and Mycom S CPM153 transmitters Biocompatibility Cytotoxicity verified in accordance with USP 2009 chapter 88 USP Class VI for diaphragm T V cert...

Page 10: ...nsors in tanks and pipes Product Configurator on the product page www endress com cpa450 Technical Information TI00183C Cleanfit CPA471 Compact stainless steel retractable assembly for installation in...

Page 11: ...rsion assembly for water and wastewater Modular assembly system for sensors in open basins channels and tanks Product Configurator on the product page www endress com cya112 Technical Information TI00...

Page 12: ...www addresses endress com...