background image

Orbisint CPS11D and CPS11

10

Hauser

Accessories

The following are the most important accessories available at the time this documentation was

issued. For accessories not listed here, please contact your service or sales office.

Assemblies

Cleanfit CPA871

• Flexible process retractable assembly for water, wastewater and the chemical industry

• For applications with standard 12mm sensors

• Product Configurator on the product page: 

www.endress.com/cpa871

Technical Information TI01191C

Cleanfit CPA875

• Retractable process assembly for sterile and hygienic applications

• For in-line measurement with standard 12 mm sensors for parameters such as pH, ORP and

oxygen

• Product Configurator on the product page: 

www.endress.com/cpa875

Technical Information TI01168C

Cleanfit CPA472D

• Robust retractable assembly for pH, ORP and other industrial sensors

• Heavy-duty version made of durable materials

• For manual or pneumatic, remote-controlled operation

• Product Configurator on the product page: 

www.endress.com/cpa472d

Technical Information TI00403C

Cleanfit CPA450

• Manual retractable assembly for installing 120 mm sensors in tanks and pipes

• Product Configurator on the product page: 

www.endress.com/cpa450

Technical Information TI00183C

Cleanfit CPA471

• Compact stainless steel retractable assembly for installation in tanks and pipes, for manual or

pneumatically remote-controlled operation

• Product Configurator on the product page: 

www.endress.com/cpa471

Technical Information TI00217C

Cleanfit CPA472

• Compact plastic retractable assembly for installation in tanks and pipes

• For manual or pneumatic, remote-controlled operation

• Product Configurator on the product page: 

www.endress.com/cpa472

Technical Information TI00223C

Cleanfit CPA473

• Stainless steel process retractable assembly with ball valve shutoff for particularly reliable

separation of the medium from the environment

• Product Configurator on the product page: 

www.endress.com/cpa473

Technical Information TI00344C

Cleanfit CPA474

• Plastic process retractable assembly with ball valve shutoff for particularly reliable separation of

the medium from the environment

• Product Configurator on the product page: 

www.endress.com/cpa474

Technical Information TI00345C

Unifit CPA442

• Installation assembly for food, biotechnology and pharmaceutics

• With EHEDG and 3A certificate

• Product Configurator on the product page: 

www.endress.com/cpa442

Technical Information TI00306C

Summary of Contents for Orbisint CPS11

Page 1: ...PTFE ring junction Can be used at pressures up to 17 bar abs 246 psi Process glass also for very alkaline applications BA and BT versions Process glass for applications in media containing hydrofluori...

Page 2: ...tegrated Ag AgCl reference system serves as the required reference electrode The transmitter converts the measured voltage into the corresponding pH value using the Nernst equation Measuring system A...

Page 3: ...operating hours under extreme measuring conditions Once the sensor has been connected the sensor data are transferred automatically to the transmitter and used to calculate the current measured value...

Page 4: ...nce converter are a thing of the past EMC safety is guaranteed by screening measures for the digital transmission of measured values Intrinsically safe electronics mean operation in hazardous areas is...

Page 5: ...ata apply only if installing with Endress Hauser assemblies Make sure to follow the installation instructions in the Operating Instructions of the used assembly 15 15 A B A0024316 2 Electrode installa...

Page 6: ...rotective goggles and suitable gloves Pressure temperature ratings absolute A C 10 12 14 16 18 B 50 100 200 250 275 300 5 0 40 80 120 160 200 246 psi p bar T F 40 0 20 60 80 100 0 4 6 8 2 T C 120 135...

Page 7: ...Ag AgCl reference lead reference 4 Advanced Gel electrolyte 5 Ag AgCl reference lead pH 6 PTFE diaphragm 7 pH glass membrane 8 Temperature sensor NTC30K 3 4 5 6 1 2 7 8 9 12 0 47 120 225 360 4 72 8 8...

Page 8: ...llar 3 Ag AgCl reference lead reference 4 Advanced Gel electrolyte 5 Ag AgCl reference lead pH 6 PTFE diaphragm 7 pH glass membrane 8 Temperature sensor Pt100 Weight 0 1 kg 0 2 lbs Materials Electrode...

Page 9: ...FM Class I Div 2 in conjunction with Liquiline M CM42 and Mycom S CPM153 transmitters Biocompatibility Cytotoxicity verified in accordance with USP 2009 chapter 88 USP Class VI for diaphragm T V cert...

Page 10: ...nsors in tanks and pipes Product Configurator on the product page www endress com cpa450 Technical Information TI00183C Cleanfit CPA471 Compact stainless steel retractable assembly for installation in...

Page 11: ...rsion assembly for water and wastewater Modular assembly system for sensors in open basins channels and tanks Product Configurator on the product page www endress com cya112 Technical Information TI00...

Page 12: ...www addresses endress com...