omnigrad M TR 44, TR 45
12
Hauser
P
1 Pt100 1/3 DIN B,
3-wire
Q
2 Pt100 1/3 DIN B,
3-wire
R
1 Pt100 1/3 DIN B,
4-wire
Y
Special version
Housing material, cable entry, IP grade
6
TA20D
Aluminium, high lid., M24x1.5
IP66
7
TA20B
Polyamide black, M20x1.5
IP65
A
TA20A
Aluminium, M20x1.5 conduit
IP66/IP67
3
TA20A
Aluminium, Pg16,
IP66/IP68
4
TA20A
Aluminium, PROFIBUS
®
connector,
IP66
B
TA20B
Polyamide white, Pg16,
IP65
C
TA20B
Polyamide black, Pg16,
IP65
E
TA21E
Aluminium, screw cap., M20x1.5
IP65
D
TA20D
Aluminium, high lid, Pg16,
IP66
5
TA20D
Aluminium, high lid, PROFIBUS
®
connector
IP66
J
TA20J
SS 316L, M20x1.5,
IP66/IP67
K
TA20J
SS 316L, M20x1.5, + display
IP66/IP67
M
TA20J
SS 316L, PROFIBUS
®
connector
IP66/IP67
R
TA20R
SS 316L, screw cap, M20x1.5
IP66/IP67
S
TA20R
SS 316L, screw cap, PROFIBUS
®
connector
IP66/IP67
W
TA20W
Aluminium, round lid, clip, Pg16
IP66
Y
Special version
Built-in head transmitter
0
Without built-in transmitter
2
TMT180-A21, 0.2 K, span limit: -200...650°C, fixed range, from...to...°C
3
TMT180-A22, 0.1 K, span limit: -50...250°C, fixed range, from...to...°C
4
TMT180-A11, 0.2 K, span limit: -200...650°C, fixed range, from...to...°C
5
TMT180-A12, 0.1 K, span limit: -50...250°C, fixed range, from...to...°C
P
TMT181-A, PCP, 2-wire, isolated, programmable, from...to...°C
Q
TMT181-B, PCP ATEX, 2-wire, isolated, programmable, from...to...°C
R
TMT182-A, HART
®
2-wire, isolated, programmable, from...to...°C
T
TMT182-B, HART
®
ATEX, 2-wire, isolated, programmable, from...to...°C
S
TMT184-A, PROFIBUS-PA
®
2-wire, isolated, programmable, from...to...°C
V
TMT184-B, ROFIBUS-PA
®
ATEX, 2-wire, isolated, program., from...to...°C
1
Built in transmitter THT1,separate position
Material certification (wetted part)
0
Certificates not required
C
3.1.B EN10204, short form certificate
E
3.1.B EN10204, roughness short form
G
3.1.B EN10204, certificate for wetted parts
H
3.1.B EN10204, roughness certificate
J
3.1.B EN10204, rou ferrite content <= 0,5%
L
3.1.B EN10204, ferrite content certificate >= 0,5%
Tests and calibration
(Minim. immersion length for calibrations is L = 90 mm; the loop
calibration is meant on the display when this is present)
0
Tests and calibration not required
1
Inspection test report (TZC135-A), sensor
2
Inspection test report (TZC135-D), loop
A
Factory calibration, single RTD, 0-100°C
B
Factory calibr., loop single RTD, 0-100°C
C
Factory calibration, double RTD, 0-100°C
E
Factory calibr., single RTD, 0-100-150°C
F
Factory. calibr., loop single RTD, 0-100-150°C
G
Factory calibr., double RTD, 0-100-150°C
J
Evaluation, single RTD, 0-100°C
K
Evaluation, single RTD, 0-100-140°C
Additional options
0
Additional options not required
TR44-
⇐
Order code