background image

omnigrad M TR 44, TR 45

6

Hauser

System components

Housing

The housing which contains the electric terminals or the transmitter, can be of different types and materials
(plastic, painted aluminium, stainless steel). The way in which it fits to the rest of the probe and the gland for
the cable entry ensures an IP grade of 65 at minimum (also refer to the figure below). All the heads supplied
have internal geometry according to DIN 43729 standard (form B), and thermometer connection M24x1.5. 
Version IP66/IP67 of head type TA20A is the basic E+H aluminium housing for temperature sensors. It is sup-
plied in the E+H corporate colours, without any extra charge.
Head TA20B is a black or white polyamide housing, sometimes defined with the code BBK in the Temperature
market. 
In TA21E a screw cap is employed and is attached to the head body by a chain.
Head type TA20D (aluminium), also referred to as BUZH, is able to contain a terminal block and a transmitter,
or

 

two transmitters at the same time.

Head TA20J is the stainless steel housing with E+H corporate design. It can also be provided with a LCD display
(4 digits), operating with 4…20 mA transmitters.
TA20R is the head suggested by E+H Temperature division for hygienic applications, because it comes in stain-
less steel and because of its "clean" design.
TA20W (BUS type) is a round grey coloured head made of aluminium, with a clip for the cap closure.
The cable glands M20x1.5 and Pg 16 supplied with the housings, accept cable diameters from 7 to 12 mm.

Fig. 5:

Housing protection grade (IP)

Head transmitter

The head-mounted transmitters available are (see also the "Electronics" section):
• TMT 180 

PCP 4…20 mA

• TMT 181

PCP 4…20 mA

• TMT 182

Smart HART

®

• TMT 184

PROFIBUS-PA

®

TMT 180 and TMT 181 are PC Programmable transmitters. TMT 180 can be supplied in a version with
improved accuracy (0.1°C vs. 0.2°C) in the bandwidth -50…250°C, and

 

a model with a fixed measurement

range (specified by the customer in the order phase) is also available.
TMT 182 output consists of 4…20 mA and HART

®

 superimposed signals.

For TMT 184, with PROFIBUS-PA

®

 output signal, the communication address can be set via software or by

means of a mechanical dip-switch. The customer may specify

 

the desired configuration in the order phase.

Fig. 6:

TMT 180, 181, 182 (left), TMT 184 (right)

Housing type

IP

Housing type

IP

Housing type

IP

Housing type

IP

TA20A

66
67
68

TA20B 65

TA20R

66
67

TA20W

66

TA20J-(without display)

66
67

TA20J-(with display) 

66
67

TA20D

66

TA21E

65

80

110

72

120

79

Ø55

85

140

98

108

11

9

108

11

3

140

95

Ø

80

Ø

4.5

Ø4

4

Ø 33

Ø

6.5

6

5

4

3

2

1

22.5

Ø 44

Ø 33

-

+

-

+

Ø

4.5

Ø4

4

Ø 33

Ø6

.5

6

5

4

3

2

1

-

+

1

8

-

+

26.8

Ø 44

Ø 33

Summary of Contents for omnigrad M TR 44

Page 1: ...nic process connections supplied as standard other on request Customized immersion length Small probe diameter or reduced tip for fast response time TR 44 Tapered or reduced tip and thermoconductive p...

Page 2: ...de the thermowell and spring loaded underneath it so as to improve the heat transfer As in TR 44 the sensing element Pt100 is positioned close to the tip of the probe The TR 45 thermowell is obtained...

Page 3: ...tions Ambient temperature housing without head mounted transmitter metal housings 40 130 C plastic housings 40 85 C Ambient temperature housing with head mounted transmitter 40 85 C Ambient temperatur...

Page 4: ...length may affect the accuracy of the sensors If it is too low an error might be gen erated in the measurement of the temperature due to the lower temperatures of the process fluid near the walls and...

Page 5: ...revices The use of purely threaded Ingold and metal to metal joints is not recommended by some hygienic design standards i e 3 A Standard 74 02 and Document 8 from EHEDG This is the reason why E H Tem...

Page 6: ...division for hygienic applications because it comes in stain less steel and because of its clean design TA20W BUS type is a round grey coloured head made of aluminium with a clip for the cap closure T...

Page 7: ...es for information regarding availability of welding adaptors The Varivent connections must be used with dedicated Tuchenhagen in line components or tank adaptors For Varivent flanges with small nomin...

Page 8: ...some sensor configurations the compliance with the requirements of BN2 can also be assured after the welding and machining operations that is in the finished product The surface roughness Ra of the we...

Page 9: ...omnigrad MTR 44 TR 45 Endress Hauser 9 Fig 9 TR 44 structure and tip designs E L D d R 3 2 20 3 5 3 Reduced...

Page 10: ...nd calibration the inspection test report consists of a declaration of conformity with the essential points of standard DIN EN 60751 The Factory calibration is carried out in the E H EA European Accre...

Page 11: ...DN 10 15 JD SMS DN 25 1 ND Conical metal to metal connection with G1 2 NE Conical metal to metal connection with M12x1 5 YY Special version Neck dimensions E 30 700 mm and d material stainless steel...

Page 12: ...P TMT181 A PCP 2 wire isolated programmable from to C Q TMT181 B PCP ATEX 2 wire isolated programmable from to C R TMT182 A HART 2 wire isolated programmable from to C T TMT182 B HART ATEX 2 wire iso...

Page 13: ...etal connection with G1 2 YY Special version Neck dimensions E 75 250 mm and d material stainless steel 5 82 mm neck length E 15 mm diameter d 6 mm neck length E to specify 15 mm diameter d 9 mm speci...

Page 14: ...from to C P TMT181 A PCP 2 wire isolated programmable from to C Q TMT181 B PCP ATEX 2 wire isolated programmable from to C R TMT182 A HART 2 wire isolated programmable from to C T TMT182 B HART ATEX 2...

Page 15: ...wire isolated programmable from to C L11 TMT182 A HART 2 wire isolated programmable from to C L21 TMT182 B HART ATEX 2 wire isolated programmable from to C L22 TMT182 C HART FM IS 2 wire isolated prog...

Page 16: ...e paste max temperature 200 C mat nr 60007126 _______________ G1 2 metal to metal weld in adapter for flus mounting of ND process connection material SS 316L 1 4435 provided with leakage detectin port...

Page 17: ...nsmitter iTEMP PCP TMT 181 TI 070R 09 en Temperature head transmitter iTEMP HART TMT 182 TI 078R 09 en Temperature head transmitter iTEMP PA TMT 184 TI 079R 09 en RTD insert for temperature sensors Om...

Page 18: ...uarter Endress Hauser GmbH Co KG Instruments International Colmarer Str 6 79576 Weil am Rhein Germany Tel 49 76 21 9 75 02 Fax 49 76 21 9 75 34 5 www endress com info ii endress com TI 244T 02 en_1204...

Reviews: