Micropilot M
22
Hauser
Operating conditions / Environment
Ambient temperature
range
Ambient temperature for the transmitter:
•
for F12-housing: -40 °C … +80 °C (-40 °F … +176 °F)
•
for T12-housing: -40 °C … +80 °C (-40 °F … +176 °F)
A weather protection cover should be used for outdoor operation if the instrument is exposed to
direct sunlight.
Storage temperature
-40 °C … +80 °C (-40 °F … +176°F)
Climate class
DIN EN 60068-2-38 (test Z/AD)
Degree of protection
•
housing: IP 65, NEMA 4X (open housing: IP20, NEMA 1)
•
antenna: IP 68 (NEMA 6P)
Vibration resistance
DIN EN 60068-2-64 / IEC 68-2-64: 20…2000 Hz, 1 (m/s²)²/Hz
Cleaning of the antenna
The antenna can get contaminated, depending on the application. The emission and reception of
microwaves can thus eventually be hindered. The degree of contamination leading to an error
depends on the medium and the reflectivity, mainly determined by the dielectric constant er. If the
medium tends to cause contamination and deposits, cleaning on a regular basis is
recommended. Care has to be taken not to damage the antenna in the process of a mechanical
or hose-down cleaning (eventually connection for cleaning liquid). The material compatibility has
to be considered if cleaning agents are used!
The maximum permitted temperature at the flange should not be exceeded.
Electromagnetic
compatibility
•
emissions according to EN 61326; equipment class B
•
compatibility according to EN 61326; appendix A (industrial area, 10 V/m) and Namur
recommendation EMC (NE 21).
Operating conditions / Process
Process temperature range
See »Ordering information« on page 32 - 38.
Process temperature limits
See »Ordering information« on page 32 - 38.
Process pressure limits
See »Ordering information« on page 32 - 38.
Dielectric constant
•
in a stilling well:
ε
r
≥
1.4
•
in free space:
ε
r
≥
1.9
www.aotewell.com
www.fa-market.com
AoteWell International.inc
Tel: +852-6563-2160