Micropilot FMR20 HART
Electrical connection
Hauser
23
6
Electrical connection
6.1
Cable assignment
-
+
1
2
A0028954
18
Cable assignment
1
Plus, brown wire
2
Minus, blue wire
6.2
Supply voltage
10.5 to 30 V
DC
An external power supply is necessary.
R [ ]
W
U0 [V]
10
10.5
21.75
20
30
0
500
A0029226
19
Maximum load R, depending on supply voltage U
0
of power supply unit
Battery operation
The sensor's
Bluetooth
® wireless technology communication can be disabled to increase
the operating life of the battery.
Potential equalization
No special measures for potential equalization are required.
Various power supply units can be ordered as an accessory from Hauser.