Operation
Dosimag
44
Hauser
Navigation
"Diagnostics" menu → Measured values → Output values
‣
Output values
Pulse output
Output frequency
Switch status
Parameter overview with brief description
Parameter
Prerequsite
Description
User interface
Pulse output
One of the following options is selected
in the
Operating mode
parameter:
• Pulse
• Automatic pulse
Displays the pulse frequency currently
output.
Positive floating-point
number
Output frequency
The
Frequency
option is selected in the
Operating mode
parameter.
Displays the value currently measured
for the frequency output.
0.0 to 10
000.0 Hz
Switch status
The
Switch
option is selected in the
Operating mode
parameter.
Displays the current switch output
status.
• Open
• Closed
11.4 Performing a totalizer reset
Function scope of the "Control Totalizer" parameter
Options
Description
Totalize
The totalizer is started.
Reset + hold
The totaling process is stopped and the totalizer is reset to 0.
hold
The totaling process is stopped and the totalizer is set to its defined start value
from the
Preset value
parameter.
Reset + totalize
The totalizer is reset to 0 and the totaling process is restarted.
totalize
The totalizer is set to the defined start value in the
Preset value
parameter and the
totaling process is restarted.
Hold
Totalizing is stopped.
Function scope of the "Reset all totalizers" parameter
Options
Description
Reset + totalize
Resets all totalizers to 0 and restarts the totaling process. This deletes all the flow
values previously totalized.