Mounting
Deltabar M PMD55 FOUNDATION Fieldbus
10
Hauser
Please note the following when mounting:
• To prevent the mounting screws from scoring, lubricate them with a multi-purpose grease
prior to mounting.
• In the case of pipe mounting, the nuts on the bracket must be tightened uniformly with a
torque of at least 30 Nm (22.13 lbf ft).
• For installation purposes, only use the screws with item number (2) (see the following
diagram).
NOTICE
Incorrect handling!
Damage of the device!
‣
Disassembly of the screws with item number (1) is not permissible under any
circumstances and will result in loss of warranty.
1
1
2
2
2
1
A0024167