Installation
CUM 750 / CUS 70
10
Hauser
3.3 Instrument
mounting
Weather protection
cover (accessories)
Meas. transmitter
Mains connection
Flexible cable duct
(customer supply)
Railing bracket
(accessories)
Railing
Bridge etc.
Immersion tube
(accessories)
CUS 70 sensor
Cleaning pump
(optional)
Basin wall
1. Before you mount the measuring
system, examine the process
environment and the physical
characteristics of the basin:
•
Basin
depth
•
Approximate location of
separation zone
•
Scrapers or other fixtures under
the water surface
2. Mount the transmitter locally (e.g.
on the scraper bridge) or at a
distance of up to 100 m from the
measuring point. When mounting,
loosen the clips on the housing ,
turn them through 180° and fix with
screws M5 / M6.
3. Mount the sensor approx. 20 cm
below this and vertical to the water
surface (e.g. with the help of an
immersion tube for cable routing).
4. Connect the sensor cable to the
terminal block of the transmitter
(see Chap. 4 Electrical Connection).
5. Connect the transmitter to the
mains.
Note:
•
When using an immersion tube, select the length the sensor projects about 30 cm into the
medium. The immersion tube must be inserted vertically into the medium.
•
For prevent kinking, we recommend the use of a flexible tube between the immersion tube and the
cable entry point to the transmitter.