Operation
CUM 750 / CUS 70
20
Hauser
6.2.2 GRAPHIC display mode
This display mode shows the strength of the feedback signal inside the basin.
This type of display is useful when the system is installed for the first time to view the material
stratification in the basin.
Sensor position
Min. height
Feedback signal: separation
zone
Max. height
Basin bottom indicator
left
right
Grid
Water surface
Basin bottom
Symbols in the GRAPHIC display
!!
Double exclamation marks indicate that the average signal strength between minimum
and maximum height lies under 100, or that the signal fails to contain the characteristics
which enable it to find a separation zone, e.g. when the sensor is moved from its original
position.
↔
↔
↔
↔
The double-ended arrow shows that the system is looking for a potential target, or that
searcher has found a target that it is now tracking.
↓↓↓↓
The down arrow shows that the sensor has found a separation zone.
*
The asterisk appears when the sonar strength has increased to such an extent that any
further representative measurement is impossible.
The triangle indicates basin bottom.
6.2.3 OVERVIEW display mode
This display mode describes one to four basins in overview format. The index indicator shows the
selected basin with the separation zone found. The number of basins shown is equal to the number of
sensors (measuring points) configured in the system settings. In this display mode, you can see the
distance between the sensor position and the separation zone (measuring mode = FROM SURFACE)
or the distance between basin bottom and the separation zone (measuring mode = FROM BOTTOM)
displayed numerically in a selected unit (m, cm, ft, in, yd). The display shows the unconditioned signal
from the sensor.
Index indicator