Weekly

"

 

Check and adjust the water level.  The water should completely cover the
honeycomb grill where the current is produced.  Water 1/2” lower than this
can create a choppy current and may cause your skimmer to draw air into the
plumbing lines.  Having the water level 1” or more higher than that
honeycomb grill will cause more water to get splashed out of the pool, and
may cause the air relief port on the top of the skimmer body to leak water.

"

 

Test the pH level at least twice a week.  Broadcast (i.e. pour chemical into the
current) pH increaser or pH decreaser to maintain levels between 7.4 and 7.8.

Winterizing the Fastlane Pool

"

 

Take the Fastlane Pool down and/or re-install indoors if in an area where harsh
winter weather occurs.

"

 

If you only close the pool, know that “Winterizing” is specific to the climate the pool
is located in.  “Winterizing” generally refers to the treatment of the water in the pool,
draining below the Fastlane Swim Unit and draining your equipment, again the pool
itself requires no special attention.

"

 

If you have any questions, please contact our Customer Service Department at 1-
800-910-2714.

"

 

If you do choose to winterize, you must drain the Fastlane Pool below all wall fittings,
Swim Unit and view ports.

"

 

When storing your pool, thoroughly clean and dry the liner and carefully roll it up.

"

 

Store your pool and Fastlane Swim Unit in a dry safe place.  Always store the hard
parts and the liner in separate boxes.

"

 

The hydraulic Power Unit can remain outside as well at the hydraulic run hoses as
the fluid inside will not freeze.  The hydraulic run hoses will need to be capped off to
prevent the fluid from draining out.

Disassembling the Fastlane Pool

"

 

Unhook the hydraulic hose connections at the Power Unit and cap all ends to prevent
hydraulic fluid from draining.

"

 

Pull the hydraulic hoses through the grommet holes (if applicable) and lift the
Fastlane Swim Unit and hanger from the pool wall.  Pull Fastlane Swim Unit out of
the pool carefully so as not to damage the pool liner.

"

 

Once the pool is drained, reach in each corner pocket and pull the liner away from
the top rail tubes.

"

 

Once the liner is loose from the top rail, walk around the outside perimeter of the
pool moving the wall back and forth to loosen the top rail and corner joints.

"

 

Begin disassembling Fastlane Pool by taking of all of the corners.

"

 

Be very careful to slowly and carefully pull the corners from the top rails.
Jolting or forcing the corner out of the top rail can create a tear in the
corner of the liner.

"

 

Once corners are off, lift top rails off of the legs and disassemble the remainder of
the pool.  Make sure the liner is rinsed and fully dry before storing.

Summary of Contents for FASTLANE POOL

Page 1: ...P5 8 08 Page 1 of 26 FASTLANE POOLTM OWNER S MANUAL...

Page 2: ...luid 11 1 Fastlane Swim Unit Housing 12 1 Fastlane Swim Unit Base with attached 25 of Hydraulic Hoses 13 1 Fastlane Hydraulic Power Unit 5 hp standard 6 hp optional 14 1 Accessory Kit which includes a...

Page 3: ...ons or in areas that may experience excess ground water A 2 x 8 x 22 piece of lumber installed under each support leg and leveled with the ground is very effective Make sure the entire base of each le...

Page 4: ...ane Pool is fully assembled you will be swimming towards the skimmer so plan accordingly 2 Align the struts G with the prepared cut outs at top of liner 3 Connect bottom tubes F to struts G one at a t...

Page 5: ...ht when facing the pool wall Refer to Diagram 2 Wider Straight Tube Layout DIAGRAM 2 WIDER STRAIGHT TUBE LAYOUT 5 Feed the connected tubes into the corresponding sleeves of the liner Remember to align...

Page 6: ...Slowly begin to fill the pool with water until the bottom of the liner is taught Remove any wrinkles in the pool liner as this time as it will be difficult to do once the pool is full 9 To prevent lea...

Page 7: ...using that secure the throat Set the throat and the screws aside to be used in Step 13 5 Set the Swim Unit Base on the cardboard box with the cylinder facing up Lay the hydraulic hoses that come pre a...

Page 8: ...ight and secure them to the top of the Swim Unit Housing using the green hose clamps provided To accomplish this unscrew the green hose clamps insert the hoses and re screw snugly into the top of the...

Page 9: ...s a total of four 4 large and two 2 small washers used in the wheel assembly Be sure that two large washers are located between each wheel and the intake grill on the back bottom of the Swim Unit base...

Page 10: ...he mark so that the mark is in the center of the grommet Trace the INSIDE of the grommet onto the liner Using a sharp blade utility knife slowly and carefully cut out the traced circle NOTE Cutting a...

Page 11: ...is to be hard wired into the 5 5 kW Electric Heater by the electrician Separately a 110 volt two speed pump with the switch on the rear of the pump and power cord with plug already wired into it done...

Page 12: ...emale slip x female slip 2 Adapter male thread x male slip 13 Nipple 1 Eyeball fitting male thread 2 Plug threaded C Additional Tools Required Tape measure Hack saw Fittings and Piping Endless Pools I...

Page 13: ...13 of 26 NOTE Pictures are not drawn to scale Parts can be ordered from Endless Pools Inc a local hardware store or a plumbing supply store QTY 1 QTY 1 QTY 9 QTY 2 QTY 2 QTY 4 QTY 2 QTY 13 QTY 3 QTY 2...

Page 14: ...icking out of the wall of the Fastlane Pool Tighten with a large pair of channel locks Make sure the nut is very snug but do not over tighten as this may crack your fitting Thread the male portion on...

Page 15: ...n in the Fastlane Pool The provided plugs can also be threaded into the threaded end of the thru wall fitting to prevent the pool from draining when the water quality system equipment needs maintenanc...

Page 16: ...nal if you need guidance on equipment location Be sure to install the ball valves hose bibb and unions in the order we have shown Their location is important for the maintenance requirements of the sy...

Page 17: ...e supplied with the circulating pump The two 2 3 8 bolts are used to fasten the circulating pump using the threaded inserts already located in the base Use the self drilling fasteners to mount the fil...

Page 18: ...ally or vertically to fit specific spaces 36 minimum vertical clearance is required to remove the filter cartridge As mentioned previously suitable drainage must be provided at both the Fastlane Pool...

Page 19: ...dition the Power Unit needs to be checked periodically for maintenance and should be easily accessible 1 Carefully remove the Power Unit from the packaging NOTE The Power Unit is heavy 2 Place the Pow...

Page 20: ...ydraulic run hose In this case fill with the full five gallons first and run the Power Unit for one minute to fill the hydraulic run hoses Turn Power Unit off and add the additional oil NOTE Do not ru...

Page 21: ...quipped with an automatic timer shutting off the system thirty 30 minutes after receiving its last command INSTALLING AN ANTENNA EXTENSION Your Fastlane remote control operates by radio waves Should t...

Page 22: ...intaining your pool water is essential to the life and health of your equipment Maintain a minimal level of 0 5 ppm free chlorine in your pool at all times as necessary Adding 1 2 cup of Clorox a day...

Page 23: ...view ports When storing your pool thoroughly clean and dry the liner and carefully roll it up Store your pool and Fastlane Swim Unit in a dry safe place Always store the hard parts and the liner in se...

Page 24: ...d be checked every two weeks Heater Optional It is very important that you read the heater literature before operating the heater During the initial 24 hour start up period you may turn on your heater...

Page 25: ...P5 8 08 Page 25 of 26 FASTLANE POOL START UP KIT Additional water quality and swimming products are always available at www myendlesspools com...

Page 26: ...ERLY BONDING OR MAINTAINING PROPER WATER CHEMISTRY pH level must be maintained between 7 4 and 7 8 and total alkalinity between 80 and 120 ppm The total dissolved solids TDS must be no greater than 3...

Reviews: