background image

UP.l1

UP.l1

HYS.U

 + 

UP.l1 HYS.U

 - 

LO.l1

LO.l1

HYS.L

 + 

LO.l1 HYS.L

 - 

Out

Out

dly.U

A.out

n.c.

 = 

A.out

n.o.

 = 

dly.U

dly.l

dly.l

Input

t

t

t

Dimensions

71

,5

mm

2

9

,5

m

m

2/

5

A

-A

0

A

0

A

0

A

-A

A

0

A

0

A

-A

0

T

3T/2

T/2

2T

T

3T/2

T/2

2T

T

3T/2

T/2

2T

T

3T/2

T/2

0

T

3T/2

T/2

2T

T

3T/2

T/2

2T

d

d

T

2T

0.308 A

0.386 A

0.000

A

0.000

A

d

T

d

T

A

A

d

T

A

d

T

2

2

0.000

1

2

A

1

2

A

2

A 1

2

A

p

1
2

A

1

A

p

2

A 1

2

A

1

2

A 1

3

A 1

3

A 1

 

ac

Ac.dc

dc

(rms)

Panel cut-out

Connection Diagram

4

5

SUPPLY:

NOTE :

184-253V AC 
50/60Hz 5VA

Line

Neutral

Not

e

:  

Cable Size: 1,5mm²

;

230V AC
Supply 

Switch

Fuse 

F 100mA 

250V AC

Fuse should be connected.

1) Mains supply cords shall meet the requirements of 
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power 
supply switch shall bring the identification of the relevant 
instrument and it should be easily accessible by the operator.

4

5

Faz

Nötr

Equipment is protected throughout by 
DOUBLE INSULATION

Holding screw 0.4-0.5Nm.  

Panel

Depth

2

61mm

5mm

Rubber
packing

Flush mounting 

clamp

1

ENDA EPV241A is intended for installation in control panels. Make sure that the device is used
only for intended purpose. The electrical connections must be carried out by a qualified staff
and must be according to the relevant locally applicable regulations. During an installation, all of the 
cables that are connected to the device must be free of electrical power. The device must be protected 
against inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is 
not exceeded. The cables should not be close to the power cables or components. 

3

5

m

m

77

mm

SET

SET

 EPV 241A

ENDA

OUT         AC         DC         ACDC

V

CAT II

1

2

3

4

5

6

7

8

9

10

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EPV241A-R-230VAC-RSI

PROGRAMMABLE 
AC/DC VOLTMETER

11 12

    OUTPUT

    250V AC 8A 

RESISTIVE LOAD

        COM.

           B

         A

8 680407 704934

230V AC +10% -20%
50/60Hz  5VA

Made in Turkey

Max. 5

00V

  AC / DC 

 

Max. 5

0V

  AC / DC 

CAT II

1

2

3

4

5

6

7

8

9

10

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EPV241A-230VAC

PROGRAMMABLE 
AC/DC VOLTMETER

11 12

8 680407 704903

230V AC +10% -20%
50/60Hz  5VA

Made in Turkey

Max. 5

00V

  AC / DC 

 

Max. 5

0V

  AC / DC 

CAT II

1

2

3

4

5

6

7

8

9

10

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EPV241A-230VAC-RSI

PROGRAMMABLE 
AC/DC VOLTMETER

11 12

        COM.

           B

         A

8 680407 704910

230V AC +10% -20%
50/60Hz  5VA

Made in Turkey

Max. 5

00V

  AC / DC 

 

Max. 5

0V

  AC / DC 

CAT II

1

2

3

4

5

6

7

8

9

10

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EPV241A-R-230VAC

PROGRAMMABLE 
AC/DC VOLTMETER

11 12

    OUTPUT

    250V AC 8A 

RESISTIVE LOAD

8 680407 704927

230V AC +10% -20%
50/60Hz  5VA

Made in Turkey

Max. 5

00V

  AC / DC 

 

Max. 5

0V

  AC / DC 

 

If

 

C.Inp

 

input type

 “

500

 is selected, the measurement terminals 9 and 12 of the terminals must be connected

Otherwise the measurement will be incorrect.   

 

If

 

C.

ı

np

  input type “

50

” is selected, the measurement terminals 10 and 11 of the terminals must be connected. Otherwise the measurement will be incorrect.

   

EPV

2

41

A

-E-0

2-R-201307

Note :  

1) Panel thickness should be maximum

 

6 mm.

2) There must be at least  60mm free space 
    behind the device, otherwise it would be 
    difficult to remove it from the panel.

For removing mounting clamps:  

-  

Push the flush-mounting clamp in direction 

1

 as                                            

shown in the  figure left.

-  

Then, pull out the clamp in direction 

2

.

Summary of Contents for EPV241A

Page 1: ...selected it is 500V DC 500V DC or If C InP 50 is selected it is 50V DC 50V DC 0 01V If C InP 50 is selected Max 5VA AC and RMS DC EPV241A E 02 R 201307 1 5 Accuracy EMC Safety requirements EN 61326 1...

Page 2: ...temperature is not exceeded The cables should not be close to the power cables or components 35mm 77mm SET SET EPV 241A ENDA OUT AC DC ACDC V CAT II 1 2 3 4 5 6 7 8 9 10 ENDA INDUSTRIAL ELECTRONICS SN...

Page 3: ...ue appears SET If key is pressed it returns to parameter name Hysteresis value for upper limit SET By using and keys hysteresis value for upper limit can be adjusted between 0 0V and 20 0V This parame...

Page 4: ...00 9600 19200 SET If key is pressed it returns to parameter name There are only The AdrS and baud parameters are only in the devices those have modbus tYPE optn CInp parameters in the devices those ha...

Page 5: ...Name 00d 0x00 Bit Relay output state 0 OFF 1 ON 1 3 DISCRETE INPUTS Coil Addresses Decimal Hex Data Type Data Content Parameter Name Read Write Permission 00d 0x00 Bit Alarm output state 0 no 1 nc Ao...

Page 6: ...e category II 1 AC RMS DC 1 1 Full scale For square wave form 2 Full scale Input Impedance 870k Frequency Range Input Range 500V 500V If CINP 500 is selected device breaks down at more than 1250 DC vo...

Page 7: ...or If C Inp input type 500 is selected the measurement terminals 1 and 4 of the terminals must be connected Otherwise the measurement will be incorrect If C np input type 50 is selected the measuremen...

Page 8: ...sed it returns to parameter name Hysteresis value for upper limit By using and keys hysteresis value for upper limit can be adjusted between 0 0V and 20 0V This parameter can t be higher than value Up...

Page 9: ...point The lower limit of the hysteresis value Delay time for the lower limit alarm Measurement method 0 AC 1 DC 2 ACDC Device address for RS485 network connection Adjustable between 1 247 Baudrate 0 O...

Page 10: ...ivity ELECTRICAL CHARACTERISTICS If C InP 500 is selected it is 0V 500V or If C nP 50 is selected it is 0 50V If C InP 500 is selected it is 500V DC 500V DC or If C InP 50 is selected it is 50V DC 50V...

Page 11: ...e according to the relevant locally applicable regulations During an installation all of the cables that are connected to the device must be free of electrical power The device must be protected again...

Page 12: ...be lower than value lo l1 HYS l HYS U If this key is pressed upper limit value appears SET If key is pressed it returns to parameter name Hysteresis value for upper limit SET By using and keys hyster...

Page 13: ...is pressed measurement input type s seen There are only The AdrS and baud parameters are only in the devices those have modbus c t r r tYPE d Pnt optn parameters in the devices those have no relay If...

Page 14: ...ork connection Adjustable between 1 247 Baudrate 0 Off 1 1200 2 2400 3 4800 4 9600 5 19200 Readable Writable ENDA EPV741A DIGITAL VOLTMETER MODBUS PROTOCOL ADDRESS MAP Input Register Addresses Read Wr...

Reviews: