7
2
m
m
7
8
m
m
PROGRAMMABLE AC/DC VOLTMETER
ENDA
EPV 741A
SET
OUT
AC
DC
ACDC
LOCK
97mm
2
2
Panel
1
1
75mm
8
4
m
m
68 mm
6
8
m
m
UP.l1
UP.l1
HYS.U
+
UP.l1 HYS.U
-
LO.l1
LO.l1
HYS.L
+
LO.l1 HYS.L
-
Out
Out
dly.U
A.out
n.c.
=
A.out
n.o.
=
dly.U
dly.l
dly.l
Input
t
t
t
2/
5
V
-V
0
ac.dc
3T/2
T/2
T
2T
0.000
V
d
T
V
1
2
V
2
V
1
1
2
V
2
V
1
3
V
1
3
V
1
19
20
EPV741A-
E
-0
2
-201406
V
-A
0
V
0
V
0
V
-V
V
0
V
0
ac
dc
T
3T/2
T/2
2T
T
3T/2
T/2
2T
T
3T/2
T/2
2T
T
3T/2
T/2
0
T
2T
T
3T/2
T/2
2T
d
d
0.308
V
0.386
V
0.000
V
d
T
V
d
T
V
d
T
2
2
0.000
1
2
V
2
V
p
1
V
p
2
V
1
2
V
1
ac
Ac.dc
dc
(rms)
230V AC +10% -20%
50/60Hz 7VA
11
12
13
14
15
OUTPUT
250V AC 8A
RESISTIVE
LOAD
S
N
: X
X
X
X
X
X
X
X
X
M
a
x
.
5
0
V
A
C
/
D
C
+
1
6
1
7
1
8
8
6
8
0
4
0
7
7
0
5
0
9
2
ENDA
INDUSTRIAL ELECTRONICS
EPV741A-R-230VAC-RSI
PROGRAMMABLE AC/DC VOLTMETER
CAT II
COM
B
A
Made in Turkey
+
M
a
x
.
5
0
0
V
A
C
/
D
C
230V AC +10% -20%
50/60Hz 7VA
19
20
11
12
13
14
15
S
N
: X
X
X
X
X
X
X
X
X
M
a
x
.
5
0
V
A
C
/
D
C
+
1
6
1
7
1
8
8
6
8
0
4
0
7
7
0
5
0
7
8
ENDA
INDUSTRIAL ELECTRONICS
EPV741A-230VAC-RSI
PROGRAMMABLE AC/DC VOLTMETER
CAT II
COM
B
A
Made in Turkey
+
M
a
x
.
5
0
0
V
A
C
/
D
C
1
7
18
Line
Neutral
C
ONNECTION DIAGRAM
Equipment is protected throughout
by
DOUBLE INSULATION
Holding screw 0.4-0.5Nm.
ENDA
EPV741A
is intended for installation in control panels.Make sure that the
device is used only for intended purpose.The electrical connections must be carried
on by a qualified staff and must be according to the relevant locally applicable
regulations. During an installation, all of the cables that are connected to the device
must be free of electrical power. The device must be protected against inadmissible
humidity, vibrations and severe soiling. Make sure that the operation temperature is
not exceeded. The cables should not be close to the power cables or components.
SUPPLY:
NOTE :
17
18
184-253V AC
50/60Hz 7VA
Line
Neutral
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100mA
250V AC
Fuse should be connected.
1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power supply switch shall bring the identification of
the relevant instrument and it should be easily accessible by the operator.
If
C.Inp
input type
“
500
”
is selected, the measurement terminals 13 and 16 of the
terminals must be connected
.
Otherwise the measurement will be incorrect.
If
C.
ı
np
input type “
50
” is selected, the measurement terminals 14 and 15 of the
terminals must be connected. Otherwise the measurement will be incorrect.
-
Push the flush-mounting clamp
in direction
1
as shown in the
figure left.
-
Then, pull out the clamp in
direction
2.
For removing mounting clamps:
Note
1)
During panel mounting, additional distance is
required for connection cables.
2)
Panel thickness should be maximum 10mm.
3)
There must be at least 90mm free space
behind the device, otherwise it would be
difficult to remove it from the panel.
Flush mounting
clamp
Rubber packing
Connection
cables
DIMENSIONS
Panel cut-out
De
pth