3.4  Connecting sensor to EDAS-10 data acquisition system 

Model EAN-90M tilt meter requires external power source of ± 12V DC (regulated) when connected to 
EDAS-10 data acquisition system. For connecting tilt meter, a multiplexer model EAM-616 is required. 16 
tilt meters can be connected to each multiplexer model EAM-616.  

Maximum input of EDAS-10 is ± 2.5 V; whereas output of tilt meter is ± 4 V at 15

0

 proportional to Sin of 

angle. A high precision attenuator is therefore required as shown in diagram below: 

 

 

 

Use EDAS-10 function P2 to read output of tilt sensor in terms of 0.5 volts. The multiplier and offset should 
be kept as 1 and 0 respectively. To get tilt angle refer to typical gage factor and formula given in relevant 
test certificate. A sample test certificate for uni-axial sensor can be referred to in section 3.5. 

 

P S card

+12V

G

-12V

1

2

3

EAM 616 2C8

1

3

2

Green
Black

Red

-12V

+12V
0V

4

6

5

Datalogger

H

Blue

A AXIS

B AXIS

White

Brown

COM

Tilt sensor

Tilt measurement with Tilt sensor and DAS

S

W

-12V

G

4

6

5

COM

CH.

*

Required for biaxial sensors only.

R1 = R2 = R3 = R4 = 100k ±0.01%, 5ppm.

*
*

R1

R2

R3

R4

*

*

L

SE

Figure 5: Tiltmeter connected to DAS  

Summary of Contents for EAN-90M

Page 1: ...gh ingenuity USERS MANUAL ENCARDIO RITE ELECTRONICS PVT LTD A 7 Industrial Estate Talkatora Road Lucknow UP 226011 India P 91 522 2661039 42 Email geotech encardio com www encardio com International U...

Page 2: ...f operation 2 2 2 Tool and accessories 2 2 3 Installation of Tiltmeter 2 2 3 1 Installation on vertical surface 3 2 3 2 Installation on horizontal surface 4 2 3 3 Installation on roof 5 3 MEASUREMENT...

Page 3: ...landslide areas Monitoring tunnels for convergence and other movement Monitoring safety of structures around zones of excavation or tunneling Monitoring deflection in bridges and struts under differe...

Page 4: ...a low thermal sensitivity The tilt meter can be fixed to any vertical surface horizontal floor or ceiling by means of suitable mounting accessories consisting of brackets and anchors These are availa...

Page 5: ...on the anchor and tighten slightly 4 Fix tilt meter on the mounting bracket with two M6 x 20 mm Allen bolts 5 Connect tilt meter with read out unit 6 Tighten anchor and Allen bolts nuts so that the t...

Page 6: ...nt 4 Insert anchors in drilled holes 5 Mount tilt meter bracket on the anchors and tighten slightly 6 Fix the tilt meter on mounting bracket with two M6 x 20 mm Allen bolts 7 Connect tilt meter with r...

Page 7: ...on anchor and tight it slightly 4 Fix the tilt meter on the mounting bracket with two M6 x 20 mm Allen bolts 5 Connect tilt meter with read out unit 6 Tighten anchor and Allen bolts nuts so that the t...

Page 8: ...3 2 Sign convention Careful orient tilt sensor during installation Make a note of the orientation Uni axial sensor measures tilt only along axis A Figure 4 shows a view from top and also convention us...

Page 9: ...ator is therefore required as shown in diagram below Use EDAS 10 function P2 to read output of tilt sensor in terms of 0 5 volts The multiplier and offset should be kept as 1 and 0 respectively To get...

Page 10: ...8367 0 0008 0 019 0 0 0000 0 0000 0 0000 0 0005 0 0000 0 0000 0 000 3 0 0524 0 8376 0 8375 0 8371 0 8376 0 0001 0 002 6 0 1046 1 6728 1 6726 1 6725 1 6730 0 0004 0 010 9 0 1565 2 5032 2 5029 2 5028 2...

Reviews: