Installation on vertical surface
1 Drill a 8 mm
Φ x
50 mm deep hole for Hilti anchor HSA M8 x 75 or equivalent on the wall of which
change in tilt has to be measured.
2 Insert anchor in the drilled hole.
3 Mount tilt meter bracket on the anchor and tighten slightly.
4 Fix tilt meter on the mounting bracket with two M6 x 20 mm Allen bolts.
5 Connect tilt meter with read-out unit.
6 Tighten anchor and Allen bolts/nuts so that the tilt meter reads almost vertical on the read-out unit.
4
Anchor (HSA M8 x 75 Hilti)
6
5
Hex. nut, SS, M6
2
3
1
Item
Tilt meter
Wall mounting bracket
Description
1
2
1
1
2
Qty.
Allen bolt, SS, M6 x 20
2
Plain washer, SS
Wall
2
1
4
3
6
5
Figure 1: Tiltmeter on vertical surface