Users’ Manual
EAN-26MH Horizontal inclinometer system
Page
|
18
5.18
Disconnect the mobile datalogger from the cable reel.
5.19
Disassemble cable from probe. Wipe clean the probe and replace protective caps on the cable
and the probe. Grease the wheel, springs and axle pivots.
5.20
Pack probe, cable holder and datalogger in the case.
5.21
Rewind cable onto the cable reel, clean it and fix the connectors in place.
5.22
Replace the two protective end caps and plug on the ends of casing and lock it. In case any
additional protection is provided, install it.
NOTE:
Frequent causes of failure of the inclinometer system are like probe is not properly cleaned,
associated cable, connectors and datalogger after the use. Not greasing the wheel, springs
and axle pivots will invariably result in costly repairs and equipment downtime.