Appendix A Serial port 485 communication protocol
49
Read inverter state 11 00 0F
No
-010B000F01A9/r
no
Read functi
on code p
ar
ameter
Auxiliary device
run command
12 00 00
No -010C00000194/r
no
Set current run
frequency
provision of
12 00 01
No -010C00010FA00
27C/r
0.01Hz Set freq.=40.00Hz
Auxiliary device
run with run freq.
provision
12 00 02 0Hz-hig
h limit
freq.
-010C00020FA00
27D/r
0.01Hz Auxiliary device
run Set
freq.=40.00Hz
Auxiliary device
forward run
12 00 03 0Hz-hig
h limit
freq.
-010C00030197/r
no
Auxiliary device
reverse run
12 00 04
No -010C00040198/r
no
Auxiliary device
forward run with
run freq.provision
12 00 05 0Hz-hig
h limit
freq.
-010C00050FA00
280/r
0.01Hz forward run
boot-strap set
freq.=40.00Hz
Auxiliary device
reverse run with
run freq.provision
12 00 06 0Hz-hig
h limit
freq.
-010C00060FA00
281/r
0.01Hz reverse run
boot-strap set
freq.=40.00Hz
Auxiliary device
stop
12 00 07
No -010C0007019B/r
no
Auxiliary device
jog run
12 00 08
No -010C0008019C/r
no
Auxiliary device
forward jog run
12 00 09
No -010C0009019D/r
no
Auxiliary device
reverse jog run
12 0A
No -010C000A01A5/
r
no
Auxiliary device
stop jog run
12 00 0B
No -010C000B01A6/
r
no
Auxiliary device
failure restoration
12 00 0C
No -010C000C01A7/
r
no
Auxiliary device
urgent stop
12 00 0D
No -010C000E01A8/
r
no
Read functi
on code
parameter
Run freq. digital
setting F0.01
13 00 01
No ~010D00010196\r 0.01Hz
Run direction
setting F0.03
13 00 03
No ~010D00030198\r 1
Accelerating time1 13 00
0A
No ~010D000E01AA
\r
0.1S
F0.08 decelerating
time1 F0.09
13 00 0B
No ~010D000F01AB
\r
0.1S
Set functio
n code
parameter
Run freq. digital
setting F0.01
14 00 01
0Hz~
High
limit
Freq.
~010E000113880
26B\r
0.01Hz Set function code
F0.01=50.00Hz
Run direction
Setting F0.03
14 00 03
0, 1 ~010E000300010
25A\r
1
Set function code
F0.03 to reverse
ENC