DEVICE CONFIGURATION
smart Econ - emz-HCW - 180116
143
›INTERNET‹ menu (Installer)
In the ›INTERNET‹ menu you can view and change the network settings of the Userinterface.
See “›INTERNET‹ menu” on page 44
At the installer level you can also define settings for sending e-mails (SMTP) and configure the con-
nection to the smart Econ Cloud.
smart Econ Cloud setup
Prerequisites:
• The smart Econ Userinterface is connected to the network and thus to the Internet via a LAN
cable.The network settings are configured correctly (DHCP activated or correct IP address etc.
entered).
The status line of the display shows: "Server: online"
• To create a login, the user requires appropriate authentication data using the TAN procedure (TAN
key / ID code not included)
In the ›INTERNET‹ menu, ›CODE‹ has a 20-digit authentication code (consisting of numbers and
lower case letters)
INTERNET
^
serial number
12345
CODE:
xxxxxxxxxxxxxxxxxxxx
renew AUTH-CODE?
NO
delete user-data?
NO
DHCP
YES
IP-Address
192.168.1.100
Subnet mask
255.255.255.0
Gatew ay
192.168.1.1
i
DNS1
0.0.0.0
DNS2
0.0.0.0
INTERNET
^
SMTP-Server
Sender
Username
Passw ord
SMTP-Port:
25
Security:
keine
Broker:
broker.com
Broker-Port:
1234
i
BACK