38 / 81
2. With the rotary switch, change the slot to 7 and click the
Load
button to
transfer the information into the Instant area.
(
Instant
= changed,
Memory
= unchanged,
Flash
= unchanged)
3. Change the Roll sensitivity to 70%
(
Instant
= changed,
Memory
= unchanged,
Flash
= unchanged)
4. Click the
Save
button to pass the information from Instant area to the slot
memory in Memory area. At this moment, the system will display an alert
button to inform you that the memory area has different information than the
flash area, so if you do not save to flash you will lose the modifications when
the system is shut down.
(
Instant
= unchanged,
Memory
= changed,
Flash
= unchanged)
5. Press the alert button to store the Memory area information in the Flash
area.
(
Instant
= unchanged,
Memory
= unchanged,
Flash
= changed)