AMETEK CTS
BS 200N100
Operating manual
V 1.12
18 / 21
8.2.
Options
•
CA BS
calibration load 50uH 0.6
Delivery :
Mains cable
2x connection cable ( 45cm)
2x Short circuit bridges
Figure 8.4. CA BS
•
AN 2050N
Artificial Network for Automotive
LISN Impedance : As per ISO 7637-2
Impedance :
5
H - 50
Current:
50A continuous, 100A short-time
Figure 8.5.: AN 2050N
•
AN 200N100
Artificial Network
LISN Impedance : As per ISO 7637-2, ISO 11452-2
CISPR16-1-2, CISPR 25
Impedance : 5
H - 50
Current:
100A continuous
Figure 8.6.: AN 200N100
•
Shunt resistor Rs
Shuntresistor for simulate the resistance of other vehicle
devices which are connected in parallel to the DUT. The
standard ISO 7637-2 defines the shuntresistor Rs.
RS-Box
10Ω, 20Ω, 40Ω, 120Ω max. 60V (30V)
Figure 8.7. RS-Box
•
R-Box LV124
Resistor box for LV124 E 10
Resistors:
0.1
Ω
, 10k
Ω
und 100k
Ω
Voltage:
60V continuous for
10kΩ and 100kΩ
Max load 0.1
Ω:
5W 10 min, 10W 5 min
Figure 8.8.: R-Box LV124