X+
Z+
Z-
Z₁-
Z₁+
X-
Pressing the key toggles between
normal 3-axes display (X, Z, Z₁) and the
summation display mode (X, Z, Z + Z₁). The
summation result is shown in the Z₁ axis
display window.
When in Summation mode the sum axis
display is aligned to the left of the display
window and the LED associated with axis
summing is illuminated.
.
.
ABS
Example: Enable Axis Summing
Ordinary
Mode
Summing
Mode
.
.
.
Z0+Z1
.
Message window will briefly
show the summing mode
.
.
ABS
.
Note:
To exit Summing mode press the key again.
The
EM250
DRO will return to the last setting of summing mode
even after the DRO was switched off.
The
EM250
DRO has a number of functions to assist in turning. These functions are
described in more detail in this section.
Lathe Functions
Radius / Diameter mode
Generally on a lathe we want to operate the cross-slide (X-axis) in Diameter mode as that reflects on the dimensions
of the part being turned. The mode can be quickly changed by pressing the key. The operating display mode is
shown by the status of the associated LED.
.
.
INC
.
.
ABS
Example: Set X-axis Diameter mode
Radius
Mode
Diameter
Mode
The
EM250
DRO will return to the last setting of radius/Diameter mode after the DRO was switched off.
Axis Summing
The
EM250
has simple internal axis summation on 3-axes Lathe units. This allows for the bed axis (Z) and compound
(Z₁) axis to be added together. For the values to be meaningful the compound axis must be rotated to be parallel
with the bed axis.