EMPYRE PRO SERIES INSTALLATION AND OPERATION MANUAL • 2009
25
REFERENCE
Furnace Specifications
FURNACE MODEL
Pro Series 100
Pro Series 200
Pro Series 400
Heating Area*
Sq. Feet
1,000 - 3,000
2,000 - 4,000
6,000 - 8,000
Sq. Metre
93 - 279
186 - 372
557 - 743
Units
in
cm
in
cm
in
cm
Log Size
Log Length
+/- 2” (5 cm)
22
56
26
66
34
86
Log Diameter
5
13
6
15
7
18
Furnace Dimensions
Furnace Width
32
81
48
122
49
124
Furnace Length
56
142
73
185
81
206
Furnace Height
67
170
81
206
96
244
Chimney Size
6
15
6
15
8
20
Loading Door Size
in
14 x 16
18 x 18
20 x 24
cm
36 x 41
46 x 46
51 x 61
Firebox Volume
5.3 cubic feet
9.3 cubic feet
20.3 cubic feet
in
16w x 21h x 28d
23w x 22h x 31d
28w x 33h x 40d
cm
41w x 53h x 71d
58w x 56h x 79d
71w x 84h x 102d
Water Capacity
US gal
30
75
115
Litres
114
284
435
Shipping Weight
lbs
1,080
2,100
2,610
kg
490
953
1,184
Note: Weights and measurements may vary slightly.
* Based on properly insulated building.
Order replacement parts through your local dealer. Identify parts by referring to components on pages 8, 9 and 24.
Replacement parts must be purchased through Pro-Fab Industries by your local dealer in order to
maintain the furnace warranty.
Summary of Contents for Pro Series 100