background image

1

Product Data

PG95XAT

CONDENSING GAS FURNACE

A11300

Utilizing the extensive resources available to Payne

R

, a new

standard of excellence has been achieved with the model

PG95XAT. The model is a unique 4--way multipoise condensing
furnace with features like no other product in its class including

two heating stages and a highly efficient ECM Blower Motor. The

PG95XAT builds on the many Payne successes in the furnace
industry and establishes a new standard for all high--efficiency gas

furnaces.

STANDARD FEATURES

S

Heating efficiency of 95.5% AFUE

S

Two heating stages

S

Highly efficient ECM blower motor

S

Humidity control when paired with a compatible condensing
unit and using a humidity sensing thermostat

S

Adjustable constant fan speed from a compatible thermostat

S

LED diagnostics and self test feature

S

Stores fault codes during power outages

S

Adjustable heating air temperature rise

S

Dehumidification terminals on control board

S

Hot surface ignition

S

Dual fuel compatible

S

Two--speed inducer motor

LIMITED WARRANTY*

S

20--year limited warranty on heat exchangers.

S

10 year parts and lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.

S

Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.

{

* For owner occupied, residential applications.

{

Jurisdictions where warranty benefits cannot be conditioned on registra-

tion will receive registered limited warranty benefits.

C E RT I F I E D

Always Ask For

Use of the AHRI Certified 

TM

 Mark indicates a

manufacturer’s participation in the program.  For
verification of certification for individual products,
go to www.ahridirectory.org.

Summary of Contents for PG95XAT

Page 1: ...ompatible thermostat S LED diagnostics and self test feature S Stores fault codes during power outages S Adjustable heating air temperature rise S Dehumidification terminals on control board S Hot surface ignition S Dual fuel compatible S Two speed inducer motor LIMITED WARRANTY S 20 year limited warranty on heat exchangers S 10 year parts and lifetime heat exchanger limited warranty to the origin...

Page 2: ...tory Supplied Media Cabinet Field Supplied Filter Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR KGAWF1506UFR Electrical Data 030040 042060 048080 048100 066120 Input Voltage Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Input Amps Amps 8 2 9 8 9 8 12 3 12 3 Unit Ampacity Amps 11 0 13 0 13 0 16 1 16 1 Minimum Wire Size AWG 14 14...

Page 3: ...100 000 BTU 120 120 000 BTU Not all familes have these models A11166 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS VALVE MAIN LIMIT SWITCH BEHIND GAS VALVE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY OPERATING INSTRUCTIONS NOT SHOWN LOCATED ON MAIN FURNACE DOOR SEE OPERATING INSTRUCTIONS INSIDE DOOR FIG...

Page 4: ...KGAHA0750P55 X X X X X Gas Orifice Kit 56 LP KGAHA0850P56 X X X X X Gas Orifice Kit 1 25mm LP KGAHA5750125 X X X X X Gas Orifice Kit 1 30mm LP KGAHA5750130 X X X X X Indoor Air Quality Media Cabinet 16 406 mm FILCABXL0016 X X X X X Media Cabinet 20 508 mm FILCABXL0020 X X X X X Media Cabinet 24 610 mm FILCABXL0024 N A N A X X X Filter Rack Bottom Return 14 356 mm Cabinet KGBFR0401B14 X N A N A N A...

Page 5: ...90 1050 2 Org 1180 1130 1095 1060 1015 975 935 895 850 800 1 Red 1100 1045 1010 970 920 885 845 790 745 690 100000 SIDE BOTTOM 5 Gry 2040 1970 1885 1795 1720 1635 1540 1450 1360 1230 4 Yel 1550 1505 1460 1415 1365 1325 1280 1230 1180 1135 3 Blu 1780 1730 1690 1645 1610 1555 1481 1400 1310 1210 2 Org 1345 1295 1250 1195 1155 1105 1055 1000 955 915 1 Red 1390 1350 1295 1260 1200 1160 1105 1050 1010 ...

Page 6: ...2 61 6 224 68 3 100 000 NA 17 5 2 94 28 7 205 62 5 229 69 8 120 000 NA NA NA 83 25 3 217 66 1 Not all families have these models NOTE See notes at end of venting tables NOTE See Table 3 for altitudes over 4500 ft 1370 M Table 2 Deductions from Maximum Equivalent Vent Length Ft M Pipe Diameter in 1 1 2 2 2 1 2 3 4 Mitered 90º Elbow 8 2 4 8 2 4 8 2 4 NA NA NA NA Medium Radius 90º Elbow 5 1 5 5 1 5 5...

Page 7: ...30 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 9001 to 10 000 2743 to 3048 40 000 5 1 5 110 33 5 115 35 1 NA NA 60 000 NA 76 23 2 142 43 3 156 47 5 NA 80 000 NA 31 9 4 103 31 4 137 41 8 142 43 3 100 000 NA NA 62 18 9 147 44 8 157 47 9 120 000 NA NA NA 51 15 5 153 46 6 Not...

Page 8: ...0 0 125 0 20 0 70 0 175 0 177 0 147 0 M 6 1 19 5 19 5 17 1 14 3 6 1 21 3 52 7 45 7 38 1 6 1 21 3 53 3 53 9 44 8 0 20 Ft 20 0 32 0 30 0 22 0 11 0 20 0 70 0 104 0 87 0 67 0 20 0 70 0 124 0 104 0 82 0 M 6 1 9 8 9 1 6 7 3 4 6 1 21 3 31 7 26 5 20 4 6 1 21 3 37 8 31 7 25 0 20 30 Ft 20 0 17 0 14 0 6 0 0 0 20 0 70 0 71 0 57 0 40 0 20 0 70 0 86 0 71 0 52 0 M 6 1 5 2 4 3 1 8 0 0 6 1 21 3 21 6 17 4 12 2 6 1 ...

Page 9: ...f heat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sides of Supply Plenum 1 in 25 mm Sides 0 0 mm Vent 0 0 mm Top of Furnace 1 in 25 mm Recommended COMBUSTION AIR PIPE FOR NON DIRECT 1 PIPE VENT AP...

Page 10: ...ased Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the other allowing venting through the inne...

Page 11: ... G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIRING Connect Y Y2 terminal as shown for proper operation Some thermostats require a C terminal connection as shown If any of the original wire as supplied must be replaced use same type or equivalent wire 208 230 OR 460 VOLT THREE PHASE 208 230 VOLT SINGLE PHASE WHT BLK WHT BLK W W1 W2 Y Y2 ...

Page 12: ...gle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560mm rectangle d For airflow requirements above 1800 CFM see Air Delivery table in Installation Instructions literature for specific use of single side inlets The use of both side inlets a combina tion of 1 side and the bottom or the bottom only return air openings may be required for airflow requirements above 1800 CFM at 0 5 in ...

Page 13: ...cessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Draft Inducer Motor Draft inducer motor shall be two speed design Primary Heat Exchangers Primary heat exchangers shall be 3 Pass corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under...

Page 14: ...s D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition Date 09 11 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No SS PG95XAT 01 Replaces New ...