ACCESSORIES

DESCRIPTION

PART NUMBER

30040

42060

48080

48100

66120

Venting, Drainage and Installation

Vent Kit - Through the Cabinet

KGADC0101BVC

X

X

X

X

X

Vent Terminal - Concentric - 2” (51 mm)

KGAVT0701CVT

X

X

X

X

N/A

Vent Terminal - Concentric - 3” (76 mm)

KGAVT0801CVT

N/A

X

X

X

X

Vent Terminal Bracket - 2” (51 mm)

KGAVT0101BRA

X

X

X

X

N/A

Vent Terminal Bracket - 3” (76 mm)

KGAVT0201BRA

N/A

X

X

X

X

CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4”

PVC

KGAAD0110PVC

X

X

X

X

X

Horizontal Trap Grommet - Direct Vent

KGACK0101HCK

X

X

X

X

X

Freeze Protect Kit - Heat Patch for Drain Trap

KGAHT0201CFP

X

X

X

X

X

Freeze Protect Kit - Heat Tape

KGAHT0101CFP

X

X

X

X

X

Furnace Base Kit for Combustible Floors

KGASB0201ALL

X

X

X

X

X

Gas Conversion

Gas Cnv Kit - Nat to LP; Two-stage

KGANP51012SP

X

X

X

X

X

Gas Cnv Kit - LP to Nat; Two-stage

KGAPN43012SP

X

X

X

X

X

Gas Orifice Kit - #42 (Nat Gas)

KGAHA0150N42

X

X

X

X

X

Gas Orifice Kit - #43 (Nat Gas)

KGAHA0250N43

X

X

X

X

X

Gas Orifice Kit - #44 (Nat Gas)

KGAHA0350N44

X

X

X

X

X

Gas Orifice Kit - #45 (Nat Gas)

KGAHA0450N45

X

X

X

X

X

Gas Orifice Kit - #46 (Nat Gas)

KGAHA0550N46

X

X

X

X

X

Gas Orifice Kit - #47 (Nat Gas)

KGAHA1550N47

X

X

X

X

X

Gas Orifice Kit - #48 (Nat Gas)

KGAHA1650N48

X

X

X

X

X

Gas Orifice Kit - #54 (LP)

KGAHA0650P54

X

X

X

X

X

Gas Orifice Kit - #55 (LP)

KGAHA0750P55

X

X

X

X

X

Gas Orifice Kit - #56 (LP)

KGAHA0850P56

X

X

X

X

X

Gas Orifice Kit - 1.25mm (LP)

KGAHA5750125

X

X

X

X

X

Gas Orifice Kit - 1.30mm (LP)

KGAHA5750130

X

X

X

X

X

Indoor Air Quality

Media Cabinet - 16” (406 mm)

FILCABXL0016

X

X

X

X

X

Media Cabinet - 20” (508 mm)

FILCABXL0020

X

X

X

X

X

Media Cabinet - 24” (610 mm)

FILCABXL0024

N/A

N/A

X

X

X

Filter Rack - Bottom Return - 14” (356 mm) Cabinet

KGBFR0401B14

X

N/A

N/A

N/A

N/A

Filter Rack - Bottom Return - 17.5” (445 mm) Cabinet

KGBFR0501B17

N/A

X

X

N/A

N/A

Filter Rack - Bottom Return - 21” (533 mm) Cabinet

KGBFR0601B21

N/A

N/A

N/A

X

N/A

Filter Rack - Bottom Return - 24.5” (622 mm) Cabinet

KGAFR0701B24

N/A

N/A

N/A

N/A

X

Filter Rack - Side Return for 1” (25 mm) Filters

KGAFR0801SRE

X

X

X

X

X

Cartridge Media Filter - 16” (406 mm)

FILXXCAR0016

X

X

X

X

X

Cartridge Media Filter - 20” (508 mm)

FILXXCAR0020

X

X

X

X

X

Cartridge Media Filter - 24” (610 mm)

FILXXCAR0024

N/A

N/A

X

X

X

EZ-Flex Filter - 16” (406 mm)

EXPXXFIL0016

X

X

X

X

X

EZ-Flex Filter - 20” (508 mm)

EXPXXFIL0020

X

X

X

X

X

EZ-Flex Filter - 24” (610 mm)

EXPXXFIL0024

N/A

N/A

X

X

X

EZ-Flex Filter with End Caps - 16” (406 mm)

EXPXXUNV0016-A09

X

X

X

X

X

EZ-Flex Filter with End Caps - 20” (508 mm)

EXPXXUNV0020-A09

X

X

X

X

X

EZ-Flex Filter with End Caps - 24” (610 mm)

EXPXXUNV0024-A06

N/A

N/A

X

X

X

Filter Pack (6 pack) - Washable - 16x25x1

(406x635x25 mm)

KGAWF1306UFR

X

X

X

X

X

Filter Pack (6 pack) - Washable - 24x25x1

(610x635x25 mm)

KGAWF1506UFR

N/A

X

X

X

X

X = Used with this model furnace
N/A = Not used with this model furnace

Summary of Contents for PG95XAT

Page 1: ...ompatible thermostat S LED diagnostics and self test feature S Stores fault codes during power outages S Adjustable heating air temperature rise S Dehumidification terminals on control board S Hot surface ignition S Dual fuel compatible S Two speed inducer motor LIMITED WARRANTY S 20 year limited warranty on heat exchangers S 10 year parts and lifetime heat exchanger limited warranty to the origin...

Page 2: ...tory Supplied Media Cabinet Field Supplied Filter Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR KGAWF1506UFR Electrical Data 030040 042060 048080 048100 066120 Input Voltage Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Input Amps Amps 8 2 9 8 9 8 12 3 12 3 Unit Ampacity Amps 11 0 13 0 13 0 16 1 16 1 Minimum Wire Size AWG 14 14...

Page 3: ...100 000 BTU 120 120 000 BTU Not all familes have these models A11166 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS VALVE MAIN LIMIT SWITCH BEHIND GAS VALVE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY OPERATING INSTRUCTIONS NOT SHOWN LOCATED ON MAIN FURNACE DOOR SEE OPERATING INSTRUCTIONS INSIDE DOOR FIG...

Page 4: ...KGAHA0750P55 X X X X X Gas Orifice Kit 56 LP KGAHA0850P56 X X X X X Gas Orifice Kit 1 25mm LP KGAHA5750125 X X X X X Gas Orifice Kit 1 30mm LP KGAHA5750130 X X X X X Indoor Air Quality Media Cabinet 16 406 mm FILCABXL0016 X X X X X Media Cabinet 20 508 mm FILCABXL0020 X X X X X Media Cabinet 24 610 mm FILCABXL0024 N A N A X X X Filter Rack Bottom Return 14 356 mm Cabinet KGBFR0401B14 X N A N A N A...

Page 5: ...90 1050 2 Org 1180 1130 1095 1060 1015 975 935 895 850 800 1 Red 1100 1045 1010 970 920 885 845 790 745 690 100000 SIDE BOTTOM 5 Gry 2040 1970 1885 1795 1720 1635 1540 1450 1360 1230 4 Yel 1550 1505 1460 1415 1365 1325 1280 1230 1180 1135 3 Blu 1780 1730 1690 1645 1610 1555 1481 1400 1310 1210 2 Org 1345 1295 1250 1195 1155 1105 1055 1000 955 915 1 Red 1390 1350 1295 1260 1200 1160 1105 1050 1010 ...

Page 6: ...2 61 6 224 68 3 100 000 NA 17 5 2 94 28 7 205 62 5 229 69 8 120 000 NA NA NA 83 25 3 217 66 1 Not all families have these models NOTE See notes at end of venting tables NOTE See Table 3 for altitudes over 4500 ft 1370 M Table 2 Deductions from Maximum Equivalent Vent Length Ft M Pipe Diameter in 1 1 2 2 2 1 2 3 4 Mitered 90º Elbow 8 2 4 8 2 4 8 2 4 NA NA NA NA Medium Radius 90º Elbow 5 1 5 5 1 5 5...

Page 7: ...30 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 9001 to 10 000 2743 to 3048 40 000 5 1 5 110 33 5 115 35 1 NA NA 60 000 NA 76 23 2 142 43 3 156 47 5 NA 80 000 NA 31 9 4 103 31 4 137 41 8 142 43 3 100 000 NA NA 62 18 9 147 44 8 157 47 9 120 000 NA NA NA 51 15 5 153 46 6 Not...

Page 8: ...0 0 125 0 20 0 70 0 175 0 177 0 147 0 M 6 1 19 5 19 5 17 1 14 3 6 1 21 3 52 7 45 7 38 1 6 1 21 3 53 3 53 9 44 8 0 20 Ft 20 0 32 0 30 0 22 0 11 0 20 0 70 0 104 0 87 0 67 0 20 0 70 0 124 0 104 0 82 0 M 6 1 9 8 9 1 6 7 3 4 6 1 21 3 31 7 26 5 20 4 6 1 21 3 37 8 31 7 25 0 20 30 Ft 20 0 17 0 14 0 6 0 0 0 20 0 70 0 71 0 57 0 40 0 20 0 70 0 86 0 71 0 52 0 M 6 1 5 2 4 3 1 8 0 0 6 1 21 3 21 6 17 4 12 2 6 1 ...

Page 9: ...f heat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sides of Supply Plenum 1 in 25 mm Sides 0 0 mm Vent 0 0 mm Top of Furnace 1 in 25 mm Recommended COMBUSTION AIR PIPE FOR NON DIRECT 1 PIPE VENT AP...

Page 10: ...ased Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the other allowing venting through the inne...

Page 11: ... G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIRING Connect Y Y2 terminal as shown for proper operation Some thermostats require a C terminal connection as shown If any of the original wire as supplied must be replaced use same type or equivalent wire 208 230 OR 460 VOLT THREE PHASE 208 230 VOLT SINGLE PHASE WHT BLK WHT BLK W W1 W2 Y Y2 ...

Page 12: ...gle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560mm rectangle d For airflow requirements above 1800 CFM see Air Delivery table in Installation Instructions literature for specific use of single side inlets The use of both side inlets a combina tion of 1 side and the bottom or the bottom only return air openings may be required for airflow requirements above 1800 CFM at 0 5 in ...

Page 13: ...cessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Draft Inducer Motor Draft inducer motor shall be two speed design Primary Heat Exchangers Primary heat exchangers shall be 3 Pass corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under...

Page 14: ...s D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition Date 09 11 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No SS PG95XAT 01 Replaces New ...