Page 20
SPCL36104-S Suction System
Pressing the “MAINTENANCE” button or “F4” on the main screen brings up the
“MAINTENANCE” menu screen. From here a choice of “ADDITIONAL SETUP
PARAMETERS”, OSCILLATOR JOG SCREEN” , or “CYCLE TROUBLE SCREEN” can
be made.
In the event that communication problems arise or the operator interface program acts
irratically, the “GO TO CONFIG SCREEN” button can be pressed.
This switches to the panelview operations setup screen where the program can be restarted
and/or setup changes made.
Again, movement between screens is performed with the touch screen or the function keys.
7.11.6
ADDITIONAL SETUP PARAMETERS
This screen allows the setting of four additional
process control variables. These variables are to be
used for fine tuning of the process and are not meant
to be continually adjusted.
“PART SURFACE SPEED” is used to set the speed
at which the part will rotate. Adjusting this setting
will speed up or slow down the mandrel rotation and
thus the surface speed the part is processed at.
“MANDREL BLOWOFF” turns ON or OFF the
flow of air thru the mandrel and into the ID of the
part.
“OSCILLATOR REFERENCE SPEED” sets the reference value used to calculate the
horizontal travel speed of the BLAST OSCILLATOR during a cycle. This is also the speed
that the largest diameter part would be run at. The actual Oscillator speed is the ratio of the
largest part diameter / the current part diameter multiplied by this reference value.
“BLOWOFF SPEED” is the travel speed of the BLAST OSCILLATOR during its
BLOWOFF stroke , return to home.
7.11.7
OSCILLATOR JOG SCREEN
This screen is used to manually position the
oscillators for assisting in setup of the guns and or
Maintenance of components. The mode of operation
must be in the MANUAL mode in order to activate
any of these motions. The Pinch Oscillator will not
move unless the cyclinders are in the UP position.
Homing of the Blast Oscillator will move the gun
assembly automatically back to their HOME
position and should be performed any time the
BLAST OSCILLATOR is jogged or the cycle is
aborted during running. This resets all required counters to allow proper operation in future
cycles.
7.11.8
CYCLE TROUBLE SCREEN
In the event that a cycle will not start, this screen
will give a possible indication as to the reason why.
All indicators should be in their “GREEN” satisfied
state in order to perform a cycle. The Media Status