SPCL36104-S Suction System
7.0
SEQUENCE OF SYSTEM OPERATION
7.1
Close all manual Blast Cabinet doors.
7.2
Press the green “SYSTEM ON” pushbutton.
NOTE:
The system may be shut down at any time by pressing the red “SYSTEM OFF”
pushbutton.
7.3
Set “Blast” selector switch to “ON”. The “LIGHTS” selector switch may be “OFF”.
7.4
Set “System” selector switch to “AUTO”.
7.5
Set the Blast Pressure as required for the parts to be processed.
7.6
Set proper parameters for the part to blasted using the OIT.
(See section 7.11 for operation of the Operator Interface Terminal OIT)
7.7
Open load door and install part over mandrel. Use the collar at the load end as a “home”
edge to properly position the part. Closing the door will engage the tail
spindle into the opened end of the mandrel to help support it. Be sure the load door is secured
before continuing. Press “CYCLE START “ button.
7.8
At end of cycle, remove the part and inspect it for an acceptable finish. If the finish is
unacceptable, make system adjustments as outlined in Section 9.0. Run new parts for
inspection after adjustments have been made.
7.9
Continue processing parts inspecting the finish of the blast treated parts.
7.10
Shut the system down. See Section 8.0.
7.11
Operator Interface Terminal (OIT)
7.11.1
When the system is powered up the “EMPIRE”
screen will appear. Press the button on the touch
screen or the “F1” soft-touch button below the
screen to switch to the “MAIN MENU” screen.