background image

19562-3-0907

Page 3

•  Due to high temperatures the appliance should be located 

out of traffic and away from furniture and draperies.

•  Children and adults should be alerted to the hazards of 

high surface temperatures and should stay away to avoid 

burns or clothing ignition.

•  Young children should be carefully supervised when they 

are in the same room as the appliance.

•  Clothing or other flammable material should not be placed 

on or near the appliance.

•  Any  safety  screen  or  guard  removed  for  servicing  an 

appliance  must  be  replaced  prior  to  operating  the 

appliance.

•  Keep burner and control compartment clean. 
•  Vent cap hot while furnace is in operation.
•  For manufactured home (USA only) or mobile home or 

residential installation convertible for use with natural 

gas and liquefied petroleum gases when provision is made 

for the simple conversion from one gas to the other. 

•  Installation and repair should be done by a QUALIFIED 

SERVICE PERSON.  The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, etc. It 

is imperative that control compartments, burners and 

circulating  air  passageways  of  the  appliance  be  kept 

clean.

•  DO  NOT  put  anything  around  the  furnace  that  will 

obstruct the flow of combustion and ventilation air.

•  DO  keep  the  appliance  area  clear  and  free  from 

combustible  material,  gasoline  and  other  flammable 

vapors and liquids.

•  DO  examine  venting  system  periodically  and  replace 

damaged parts.

•  DO make a periodic visual check of burner. Clean and 

replace damaged parts.

•  DO NOT use this heater if any part has been under water. 

Immediately call a qualified service technician to inspect 

the heater and to replace any part of the control system 

and any gas control which has been under water. 

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

IMPORTANT SAFETY INFORMATION

Summary of Contents for DV-20E

Page 1: ...Series in Canada This appliance is only for use with the type s of gas indicated on the rating plate A conver sion kit is supplied with the appliance Installer Leave this manual with the appli ance C...

Page 2: ...nts for Massachusetts 5 Introduction 6 Speci cations 6 Gas Supply 7 Gas Conversion Instructions 8 Clearances 9 Furnace Installation 9 12 Lighting Instructions 13 Wiring 14 Maintenance 15 Operation and...

Page 3: ...on and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected before use and at least annually by a quali ed service person More frequent cleaning may be required due to...

Page 4: ...ot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorpt...

Page 5: ...iredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE Ametalorplasticidenti cationplateshallbe permanently mounted to the exterior...

Page 6: ...corporationorcompanywhicheitherin person or through a representative is engaged in and is responsible for a the installation or replacement of gas piping or b the connection installation repair or ser...

Page 7: ...ped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the g...

Page 8: ...s conversion label are provided in conversion kit attached to manifold pipe 1 Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit 2 Open brass union loca...

Page 9: ...uld be a minimum horizontal distant of six 6 feet 1 83m from any pressure regulator In case of regulator malfunction the six 6 feet 1 83m distance will reduce the chance of gas entering the vent cap I...

Page 10: ...it is vented directly out the back using the concentric vent tube assembly provided See Figure 2 for vent hole location This hole location can be conveniently moved closer to unit exhaust outlet tube...

Page 11: ...d conform to ASTM Standard D2564 for PVC or D2235 for ABS This PVC or ABS pipe must not be used for the exhaust vent pipe run Note Type SDR pipe is not approved for use in Canada For new construction...

Page 12: ...the condensate drain pan located within the appliance Whenever a horizontal vent run is used where local codes allow you can slope the exhaust pipe downward to the outside 1 4 6mm per foot 305mm The d...

Page 13: ...ance and to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electri...

Page 14: ...alled turn off gas supply and electric supply 2 Remove casing front 3 Remove black hose from front nipple on pressure switch 4 Remove junction box cover 4 screws 5 Please refer to wiring diagram for r...

Page 15: ...and then turn temperature control knob clockwise slowly till furnace turns on For typical room comfort the control knob should be pointed toward medium 2 The furnace control board follows sequence of...

Page 16: ...lashes Pressure switch is closed with inducer off Check Pressure Switch and Replace 4 Flashes Lockout due to failed ignition Check for Broken Ignitor Check for Bent Ignitor Bracket Ignitor too far fro...

Page 17: ...d the Description of each part from the following appropriate illustration and list Be sure to give all this information Furnace Model Number Part Description Furnace Serial Number Part Number Type of...

Page 18: ...19562 3 0907 Page 18 PARTS VIEW...

Page 19: ...19562 3 0907 Page 20 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...