background image

27061-4-1213

Page 22

to order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.

com. to provide warranty service, your dealer will need your name and address, purchase date and serial number, and the 

nature of the problem with the unit. 

to order Parts after the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below. 

this list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com.

Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered original 

Equipment repair parts for Heaters, grills, and Fireplaces manufactured by Empire Comfort Systems inc. 

MASTer pArTS DISTrIbuTOr LIST

parts Not under warranty

Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distribu-

tors list.  For best results, the 

service person or dealer

 should order parts through the distributor. Parts can be shipped directly to the 

service person/dealer

.

warranty parts

Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is 

required

 for 

warranty parts.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number and Serial Number from the 

name plate on your equipment. then determine the Part number (

not

 the index number) and the Description of each part from the fol-

lowing illustration and part list. Be sure to give all this information . . .

appliance Model number  

      Part Description 

appliance Serial number 

 

Part number  

type of gas (Propane or natural) 

Do not order bolts, screws, washers or nuts. they are standard hardware items and can be purchased at any local hardware store. 

Shipments contingent upon strikes, fires and all causes beyond our control.

hOw TO OrDer repAIr pArTS

Dey Distributing

1401 Willow Lake Boulevard

Vadnais Heights, Mn 55101

phone: 

651-490-9191

Toll free:

 800-397-1339

Website:

 www.deydistributing.com

parts: heater, hearth and grills

Victor Division of F. W. Webb Company

200 Locust Street

Hartford, Ct 06114

phone:

 860-722-2433

Toll free: 

800-243-9360

fax: 

860-293-0479

Toll free fax:

 800-274-2004

Websites: 

www.fwwebb.com & www.victormfg.com

parts: heater, hearth and grills

east coast energy products

10 East Route 36

West Long Branch, nJ 07764

phone: 

732-870-8809

Toll free:

 800-755-8809

fax: 

732-870-8811

Website: 

www.eastcoastenergy.com

parts: heater, hearth and grills

Able Distributors

2501 north Central avenue

Chicago, iL 60639

phone: 

773-889-5555

Toll free:

 800-880-2253

fax:

 773-466-1118

Website: www. abledistributors.com

parts: heater

Summary of Contents for VFP32FB2CF-3

Page 1: ...consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO...

Page 2: ...8 9 Gas Line Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional Single Speed Blower Installations Instructions 13 15 Junction Box Wiring Installation Instructions 16 Maintena...

Page 3: ...val of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is opera...

Page 4: ...finishing materials may extend to the top standoff screws on the front edge of the outer wrap See Figures 2a 2b CLEARANCES 45 6 3 MAX PERPENDICULAR SIDE WALL FRONT FACE SIDE FIREBOX TOP VIEW COMBUSTI...

Page 5: ...he grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox MANTEL STANDARD HOOD 13 10 12 MAX 11 1 2 MIN FIREBOX FACE CEILING COMBUSTIBLES ALLOWED 3 8 COMBUST...

Page 6: ...e or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what compo...

Page 7: ...39 1 2 43 1 2 34 1 2 39 1 2 43 1 2 C 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 D 27 1 4 32 1 4 36 1 4 27 1 4 32 1 4 36 1 4 E 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 F 31 36 40 31 36 40 G 27 13...

Page 8: ...desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then sl...

Page 9: ...STALL Contact your dealer for proper model Always use an external regulator for all LP fireboxes to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted t...

Page 10: ...h Air Kit is designed to introduce outside air to the firebox as desired It must be installed prior to or at the time of firebox installa tion to framing The Fresh Air kit must be installed prior to t...

Page 11: ...t of the outside duct connection prior to securing the out side rain cap hood to the building 2 Secure the 4 dia duct to the Slide Assembly collar on the firebox with band clamps or screws installer s...

Page 12: ...t Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer R 3580 PHILLIPS TRUSS HEAD SCREW 10 X QTY 2 R 2737 HEX HEAD SCREW 10 X BLACK QTY 4 R 1134 HEX HEAD SLOTTED SCREW 10 X 1 QTY 4 OPTIONAL FRESH A...

Page 13: ...f the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 25 1 If installed turn OFF gas supply to firebox gas log 2 If applicable...

Page 14: ...1 4 female terminal that must be attached to the open terminal on the blower motor See Figure 32 Connection A 9 The other fan control wire has a 1 4 male terminal Attach this terminal to the open ter...

Page 15: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control...

Page 16: ...box Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Page 17: ...3 R9293 HEARTH LEDGE LEFT 20 R9294 R9294 R9294 R9294 HEARTH LEDGE CENTER 21 23004 23004 23004 23004 RETAINER HEARTH INDEX NO PART NUMBER DESCRIPTION VFP36FB2DL VFP36FB2EL VFP36FB2CL VFP36FB2DF VFP36FB...

Page 18: ...JUNCTION BOX 8 19945 19945 21642 19945 19945 21642 BRACKET TOP BRICK RETAINER 9 19401 19401 19401 19401 19401 19401 BRACKET BOTTOM BRICK RETAINER 10 R8672 R9421 R8285 R8672 R9421 R8285 BRICK PANEL RI...

Page 19: ...27061 4 1213 Page 19 PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 17 21 19 20 18...

Page 20: ...Air Kit 1 2 8 4 7 6 5 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits Standard 3 Piece Frame Kits Black Brass Stainless Steel or Hammered Pewter Extruded Aluminum Frame Kits Black Brass Stainless Stee...

Page 21: ...ss Steel finishes Contact dealer for all available optional louver accessories Bottom Trim Strip Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel finishes Contact dealer...

Page 22: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 23: ...of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and op...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...