4.  Insert blower assembly into interior, bottom of firebox. Posi

-

tion blower assembly so that you align the notch on back of 

blower assembly with the center screw on firebox back, then 

push the blower assembly against firebox back. The blower 

wheel must be centered with the back wall of the firebox. The 

magnets on the back and bottom of blower assembly will suf-

ficiently hold blower assembly in place.

Note: 

For field installation of blower assembly, it may be easier to 

remove rear cover panel to install blower. this eliminates 

the need to remove brick liner panels, but the blower would 

have to be installed prior to installing the firebox into a wall 

or chase. 

See figure 28.

REAR COVER PANEL MAY BE
REMOVED TO INSTALL BLOWER

REINSTALL COVER AFTER
BLOWER IS INSTALLED

figure 28

5.  once the blower assembly is in position, locate the plug but-

ton in the top right rear corner of the firebox. Remove the plug 

with a standard screwdriver and discard plug.

6.  Next, find the fan control switch and wire assembly. Feed the 

wires through the hole at the top of the firebox, and secure 

the fan control switch with (2) #6 screws provided. 

See figure 

29.

FAN CONTROL
SWITCH LOCATION

FAN CONTROL WIRES

figure 29

7.  The fan control wires will slide down between the firebox and 

outer wrap near the blower assembly. 

See figure 29

.

8.  one fan control wire will have a 1/4” female terminal that must 

be attached to the open terminal on the blower motor. 

See 

figure 32, connection A.

9.  the other fan control wire has a 1/4” male terminal. attach this 

terminal to the open terminal on the blower power cord. 

See 

figure 32, connection b

10.  Route the wires away from moving parts of the blower assem-

bly and retain wires together near the blower motor using the 

plastic purse clip provided.

11.  to complete the installation, plug the power cord into the junc-

tion box receptacle at the right rear corner of the firebox outer 

wrap. 

See figure 30.

12.  if room permits, the power cord can be located from the out-

side of the unit looking through the junction box access hole 

(with the junction box removed), then plug up the power cord 

before reinstalling the pre-wired junction box.

13.  once all connections are made electrically, it is recommended 

that you test the blower fan control operation by turning on 

power to the blower (Caution: 110 Volt). then apply heat to 

the fan control switch inside the firebox with a lighter or match 

until blower is activated. once blower is activated, check for 

proper operation. Do not place hands near blower assembly 

or other wiring while power is on.

14.  Replace blower access plate and/or reinstall the brick liner 

panels if provided.

15.  this completes the installation of the optional FBB5 Blower kit 

accessory.

Note: 

this blower is equipped with a heat activated fan control 

switch. Blower will operate when the firebox warms up, and 

will turn off automatically when the firebox cools down.

figure 30

BLOWER POWER CORD

Summary of Contents for VFP32FB2CF-3

Page 1: ...consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO...

Page 2: ...8 9 Gas Line Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional Single Speed Blower Installations Instructions 13 15 Junction Box Wiring Installation Instructions 16 Maintena...

Page 3: ...val of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is opera...

Page 4: ...finishing materials may extend to the top standoff screws on the front edge of the outer wrap See Figures 2a 2b CLEARANCES 45 6 3 MAX PERPENDICULAR SIDE WALL FRONT FACE SIDE FIREBOX TOP VIEW COMBUSTI...

Page 5: ...he grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox MANTEL STANDARD HOOD 13 10 12 MAX 11 1 2 MIN FIREBOX FACE CEILING COMBUSTIBLES ALLOWED 3 8 COMBUST...

Page 6: ...e or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what compo...

Page 7: ...39 1 2 43 1 2 34 1 2 39 1 2 43 1 2 C 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 D 27 1 4 32 1 4 36 1 4 27 1 4 32 1 4 36 1 4 E 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 F 31 36 40 31 36 40 G 27 13...

Page 8: ...desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then sl...

Page 9: ...STALL Contact your dealer for proper model Always use an external regulator for all LP fireboxes to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted t...

Page 10: ...h Air Kit is designed to introduce outside air to the firebox as desired It must be installed prior to or at the time of firebox installa tion to framing The Fresh Air kit must be installed prior to t...

Page 11: ...t of the outside duct connection prior to securing the out side rain cap hood to the building 2 Secure the 4 dia duct to the Slide Assembly collar on the firebox with band clamps or screws installer s...

Page 12: ...t Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer R 3580 PHILLIPS TRUSS HEAD SCREW 10 X QTY 2 R 2737 HEX HEAD SCREW 10 X BLACK QTY 4 R 1134 HEX HEAD SLOTTED SCREW 10 X 1 QTY 4 OPTIONAL FRESH A...

Page 13: ...f the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 25 1 If installed turn OFF gas supply to firebox gas log 2 If applicable...

Page 14: ...1 4 female terminal that must be attached to the open terminal on the blower motor See Figure 32 Connection A 9 The other fan control wire has a 1 4 male terminal Attach this terminal to the open ter...

Page 15: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control...

Page 16: ...box Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Page 17: ...3 R9293 HEARTH LEDGE LEFT 20 R9294 R9294 R9294 R9294 HEARTH LEDGE CENTER 21 23004 23004 23004 23004 RETAINER HEARTH INDEX NO PART NUMBER DESCRIPTION VFP36FB2DL VFP36FB2EL VFP36FB2CL VFP36FB2DF VFP36FB...

Page 18: ...JUNCTION BOX 8 19945 19945 21642 19945 19945 21642 BRACKET TOP BRICK RETAINER 9 19401 19401 19401 19401 19401 19401 BRACKET BOTTOM BRICK RETAINER 10 R8672 R9421 R8285 R8672 R9421 R8285 BRICK PANEL RI...

Page 19: ...27061 4 1213 Page 19 PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 17 21 19 20 18...

Page 20: ...Air Kit 1 2 8 4 7 6 5 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits Standard 3 Piece Frame Kits Black Brass Stainless Steel or Hammered Pewter Extruded Aluminum Frame Kits Black Brass Stainless Stee...

Page 21: ...ss Steel finishes Contact dealer for all available optional louver accessories Bottom Trim Strip Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel finishes Contact dealer...

Page 22: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 23: ...of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and op...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: