background image

27061-4-1213

Page 3

The installation must conform with local codes or, in 

the absence of local codes, with the National Fuel Gas 

code, ANSI z223.1 (latest edition) and to the National 

electrical code, ANSI/NfpA70 (latest edition).

NOTE: Installation and repair should be done by a quali

-

fied service person. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due 

to excessive lint from carpeting, bedding material, etc. 

It is imperative that control compartment, burners and 

circulating air passageways of the appliance be kept 

clean.

Any safety screen or guard removed for servicing an 

appliance must be replaced prior to operating the ap

-

pliance. Provide adequate combustion and ventilation 

air.

The flow of combustion and ventilation air MUST NOT 

be obstructed.

provide adequate clearance around air openings into 

the  combustion  chamber  and  adequate  accessibility 

clearance for servicing and proper operation. Never 

obstruct the front opening of the appliance.

This  Empire  Comfort  Systems,  Inc.  firebox  and  its 

components have been tested and will operate safely 

when installed in accordance with this installation 

manual.  Read  all  instructions  before  starting 

installation, then follow these instructions carefully 

during  installation  to  maximize  firebox  benefit  and 

safety. report to your dealer any parts damaged in 

shipment.

The  Empire  Comfort  Systems,  Inc.  warranty  will  be 

voided by, and Empire Comfort Systems, Inc. disclaims 

any responsibility for the following actions:

-  Installation of any damaged firebox.

-  Modification of the firebox or any of the components 

parts thereof.

-  Installation  other  than  as  instructed  by  Empire 

comfort Systems, Inc.

-  Installation and/or use of any component part 

or  accessory  not  approved  by  Empire  Comfort 

Systems,  Inc.  in  combination  or  assembly  with 

a  Empire  Comfort  Systems,  Inc.  firebox,  not 

withstanding  any  independent  testing  laboratory 

or other third party approval of such component 

part or accessory.

Any such action may create a possible fire hazard.

Consult your local building codes.
Firebox Screen.

The firebox screen must be in place when the firebox 

is operating.

Instructions to Installer

1.  installer must leave instruction manual with owner after 

installation.

2.  Installer must have owner fill out and mail warranty card 

supplied with firebox.

3.  installer should show owner how to start and operate 

log set that is installed into firebox.

Important

all correspondence should refer to complete Model number, 

Serial number.
notice:

  During  initial  firing  of  this  firebox  with  a  log  set 

installed, its paint will bake out, and smoke will occur. to 

prevent triggering of smoke alarms, ventilate the room in 

which the unit is installed.

Qualified Installing Agency

installation and replacement of gas piping, gas utilization 

equipment or accessories and repair and servicing of 

equipment shall be performed only by a qualified agency. 

The  term  "qualified  agency"  means  any  individual,  firm, 

corporation or company which either in person or through 

a representative is engaged in and is responsible for (a) 

the installation or replacement of gas piping or (b) the 

connection, installation, repair or servicing of equipment, 

who is experienced in such work, familiar with all precautions 

required and has complied with all the requirements of the 

authority having jurisdiction.

State of Massachusetts: the installation must be made 

by a licensed plumber or gas fitter in the Commonwealth 

of Massachusetts. the state of Massachusetts requires 

that a flexible appliance connector cannot exceed three 

feet in length.
Sellers of unvented propane or natural gas-fired 

supplemental room heaters shall provide to each 

purchaser a copy of 527 CMR 30 upon sale of the unit.
in the State of Massachusetts, unvented propane and 

natural  gas-fired  space  heaters  shall  be  prohibited  in 

bedrooms and bathrooms.

the installation must conform with local codes or, in the 

absence of local codes, with the national Fuel gas Code, 

anSi Z223.1/nFPa 54.*

*available from the american national Standards institute, inc., 

11 West 42nd St., new York, n.Y. 10036.

iMPoRtant SaFEtY inFoRMation

intRoDUCtion

Summary of Contents for VFP32FB2CF-3

Page 1: ...consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO...

Page 2: ...8 9 Gas Line Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional Single Speed Blower Installations Instructions 13 15 Junction Box Wiring Installation Instructions 16 Maintena...

Page 3: ...val of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is opera...

Page 4: ...finishing materials may extend to the top standoff screws on the front edge of the outer wrap See Figures 2a 2b CLEARANCES 45 6 3 MAX PERPENDICULAR SIDE WALL FRONT FACE SIDE FIREBOX TOP VIEW COMBUSTI...

Page 5: ...he grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox MANTEL STANDARD HOOD 13 10 12 MAX 11 1 2 MIN FIREBOX FACE CEILING COMBUSTIBLES ALLOWED 3 8 COMBUST...

Page 6: ...e or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what compo...

Page 7: ...39 1 2 43 1 2 34 1 2 39 1 2 43 1 2 C 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 D 27 1 4 32 1 4 36 1 4 27 1 4 32 1 4 36 1 4 E 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 F 31 36 40 31 36 40 G 27 13...

Page 8: ...desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then sl...

Page 9: ...STALL Contact your dealer for proper model Always use an external regulator for all LP fireboxes to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted t...

Page 10: ...h Air Kit is designed to introduce outside air to the firebox as desired It must be installed prior to or at the time of firebox installa tion to framing The Fresh Air kit must be installed prior to t...

Page 11: ...t of the outside duct connection prior to securing the out side rain cap hood to the building 2 Secure the 4 dia duct to the Slide Assembly collar on the firebox with band clamps or screws installer s...

Page 12: ...t Assembly 2 29257 Slide Assembly 3 29263 Handle Retainer R 3580 PHILLIPS TRUSS HEAD SCREW 10 X QTY 2 R 2737 HEX HEAD SCREW 10 X BLACK QTY 4 R 1134 HEX HEAD SLOTTED SCREW 10 X 1 QTY 4 OPTIONAL FRESH A...

Page 13: ...f the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 25 1 If installed turn OFF gas supply to firebox gas log 2 If applicable...

Page 14: ...1 4 female terminal that must be attached to the open terminal on the blower motor See Figure 32 Connection A 9 The other fan control wire has a 1 4 male terminal Attach this terminal to the open ter...

Page 15: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control...

Page 16: ...box Install a UL listed cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Page 17: ...3 R9293 HEARTH LEDGE LEFT 20 R9294 R9294 R9294 R9294 HEARTH LEDGE CENTER 21 23004 23004 23004 23004 RETAINER HEARTH INDEX NO PART NUMBER DESCRIPTION VFP36FB2DL VFP36FB2EL VFP36FB2CL VFP36FB2DF VFP36FB...

Page 18: ...JUNCTION BOX 8 19945 19945 21642 19945 19945 21642 BRACKET TOP BRICK RETAINER 9 19401 19401 19401 19401 19401 19401 BRACKET BOTTOM BRICK RETAINER 10 R8672 R9421 R8285 R8672 R9421 R8285 BRICK PANEL RI...

Page 19: ...27061 4 1213 Page 19 PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 17 21 19 20 18...

Page 20: ...Air Kit 1 2 8 4 7 6 5 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits Standard 3 Piece Frame Kits Black Brass Stainless Steel or Hammered Pewter Extruded Aluminum Frame Kits Black Brass Stainless Stee...

Page 21: ...ss Steel finishes Contact dealer for all available optional louver accessories Bottom Trim Strip Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel finishes Contact dealer...

Page 22: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 23: ...of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and op...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: