Figure 27
WARNING
NEVER operate fireplace with an optional weather door in place.
In normal operation on high after 10 to 15 minutes, the flame ap-
pearance should be several tongues of yellow flames.
NOTe:
All flames will be random by design, flame height will go
up and down.
During manufacture, fabricating, and shipping, various components
of this fireplace are treated with oils, films, or bonding agents. These
are not harmful, but may produce smoke and smells as they are
burned off during the initial operation of the fireplace. This is normal.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Any odors remaining after this initial break-in
will disappear with continued use.
Flames from the main burner should be visually out before the
weather door is installed.
If burner flame pattern is incorrect
• See Troubleshooting, page 28.
Flame pattern
The main burner flame will be mostly yellow.
Flame Ignition and extinction
When the main burner is ignited it may take up to a minute for the
full flame pattern to develop.
When the main burner is extinguished it may take up to a minute for
the flames to disappear. It is normal to have the flames burn down
near the burner, as the remaining gas is burned.
MAIN BURNeR FlAMe cHARAcTeRISTIcS
Figure 28 - correct Flame propane
Figure 29 - correct Flame Natural
Figure 30 - Incorrect Short Blue Flame
Figure 31 - Incorrect Tall Yellow Flame