Page 33
Installation and Operation Manual - Gateway 3500
ENGLISH
8.1.9 Mobile Home With Heat Shield AC02710 or AC02762
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
18
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
7 ¾" (197 mm)
7 ¾" (197 mm)
B
5" (127 mm)
5" (127 mm)
E
15
⅞
" (403 mm)
15
⅞
" (403 mm)
C
3" (76 mm)
3" (76 mm)
F
13 ¾" (349 mm)
13 ¾" (349 mm)
8.2 Floor Protection
This stove is designed to prevent the floor from overheating. However, it must be placed on a
non-flammable surface to protect the floor from hot embers that may fall during loading. The
floor protection must be a continuous, non combustible material, such as steel with a minimum
thickness of 0.015" (0.38 mm) or ceramic tiles sealed together with grout. Cement board, brick,
or any other approved or listed material suited for floor protection. No R factor required.
A material is considered non-combustible when made entirely of steel, iron,
bricks, tiles, concrete, slate, glass or a combination of these materials.
Materials corresponding to ASTM E136 and UL 763 are considered to be
non-combustible materials with the exception of gypsum.
Any type of tile will require a continuous non combustible sheet beneath to prevent the possibility
of embers falling through to the combustible floor if cracks or separation should occur in the
finished surface. Check local codes for approved alternatives. No protection is required if the
unit is installed on a non-combustible floor (ex: concrete).
FLOOR PROTECTION
Canada
USA
G
19
8" (203 mm)
N/A
H
8" (203 mm)
N/A
I
18" (457 mm) From
door opening
16" (203 mm) From
door opening
J
N/A
8" (203 mm)
N
N/A
See Note
20
18
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
19
The floor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm).
20
Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm).
«Figure 15: Clearances - Side»
H
I
G
J