background image

34961-2-1015

Page 25

INSERT MAINTENANCE AND SERVICE

Although the frequency of servicing and maintenance will depend 

on use and the type of installation, you should have a qualified 

service technician perform an appliance checkup at the beginning 

of  each  heating  season.  Specific  guidelines  regarding  each 

appliance maintenance task are listed below.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING 

YOUR APPLIANCE.

Cleaning Burner and Controls

Frequency: 

Once annually.

By: 

Qualified service technician.

Task: 

Brush or vacuum the control compartment.

Checking Flame Patterns, Flame Height

Frequency: 

Periodically.

By: 

Qualified service technician/Home owner.

Task: 

Make a visual check of your fireplace’s flame patterns.

Make sure the flames are steady - not lifting or floating. The flame 

sensor tips should be covered with flame. 

Figure 42

 - 

Correct Flame Pattern

Notice:

 Natural Gas flames maybe be taller than the ones 

shown in the above graphic.

Checking Vent System

Frequency: 

Before initial use and at least annually thereafter, 

more frequently if possible.

By: 

Qualified service technician/Home owner.

Task: 

Inspect the external vent cap on a regular basis to ensure 

that no debris is interfering with the flow of air. Inspect entire vent 

system for proper function.

Glass Cleaning

It will be necessary to clean the glass periodically. During start-up 

condensation, which is normal, forms on the inside of the glass and 

causes lint, dust and other airborne particles to cling to the glass 

surface. Also initial paint curing may deposit a slight film on the 

glass. It is therefore recommended that the glass be cleaned two or 

three times with a non-abrasive household cleaner and warm water 

(we recommend gas fireplace glass cleaner). After that the glass 

should be cleaned two or three times during each heating season 

depending on the circumstances present.

General Glass Information

 

WARNING

Do not operate appliance with the glass front removed, 

cracked or broken. Replacement of the glass should be done 

by a licensed or qualified service person.

Only glass approved for use by the manufacturer in fireplace may 

be used for replacement. The glass replacement should be done 

by a licensed or qualified service person.

 

WARNING

1.  The use of substitute glass will void all product warranties.

2.  Care must be taken to avoid breakage of the glass.

3.  Under no circumstances should this appliance be operated 

without the glass front or with a broken glass front. Replacement 

of the glass (with gasket) as supplied by the manufacturer 

should be done by a qualified service person.

4.  Do not abuse the glass by striking or hitting the glass.

 

WARNING

Do not use abrasive cleaners on glass. Do not attempt to 

clean glass when glass is hot.

Summary of Contents for DXL30IN91N-2

Page 1: ...ch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you c...

Page 2: ...ts 1 2 3 4 6 7 8 5 BEFORE YOU START 1 Read the safety information on Pages 32 33 2 Install the wiring See page 18 3 Install the venting See pages 9 11 4 Install the fireplace See pages 9 11 5 Connect...

Page 3: ...14 BURNER COVER REMOVAL PLACEMENT 15 DECORATIVE MEDIA PLACEMENT 16 LIGHTING INSTRUCTIONS 17 IPI SYSTEM WIRING DIAGRAM 18 REMOTE CONTROL OPERATION INSTRUCTIONS 19 24 INSERT MAINTENANCE AND SERVICE 25...

Page 4: ...with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from theAmerican National Standards Institute Inc 11 West 42nd St New Yo...

Page 5: ...Model Description Used On DS3066BL 3 Sided 1 Piece Matte Black DXL30IN DS3566BL 3 Sided 1 Piece Matte Black DXL35IN REFLECTIVE LINERS Model Description Used On DVP30CKR Black 30 Inch DXL30IN DVP30CWR...

Page 6: ...irements Proper opening size of fireplace required for installation of the fireplace insert INSERT DIMENSIONS in inches DIMENSION DXL30IN DXL35IN A 20 1 8 24 1 16 B 29 3 8 33 3 8 C 18 5 8 21 3 4 D 15...

Page 7: ...m Face of Fireplace dimensions in inches Height Above Top of Insert dimensions in inches A 10 F 14 B 8 G 17 1 2 C 6 H 21 1 2 D 3 I 24 1 4 E 1 2 J 27 The minimum distance to the room ceiling from the T...

Page 8: ...size or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied pe...

Page 9: ...e the exposed grille area should be left open NOTICE Surround panel kits have been tested and approved to cover existing air circulation vents or grilles NOTICE Cutting of sheet metal parts of a firep...

Page 10: ...a zero clearance factory built wood burning fireplace the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily Con...

Page 11: ...34961 2 1015 Page 11 VENTING AND INSTALLATION Figure 9...

Page 12: ...n the flex venting and subsequently dripping out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having exterior portio...

Page 13: ...ssembly Figure 13 5 Repeat step 4 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of the clip while pulling injury may occur Ensure that the latch tool i...

Page 14: ...pull the latch out and up until it engages to the glass assembly Figure 16 5 Repeat step 4 through 5 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of...

Page 15: ...urner cover out from the back past the front of the unit Tilt the burner cover to the side and lift out See Figures 19 and 20 Set the burner cover aside Figure 19 Figure 20 Note Install firebox liners...

Page 16: ...2 3 Bag or 1lb 10 oz 1 Bag or 2 lbs DXL30IN LP Approximately 2 3 Bag or 1lb 10 oz 1 Bag or 2 lbs DXL35IN NAT 3 4 Bag or 1lb 8 oz 2 Bags or 2 lbs 8 oz DXL35IN LP Not Allowed 2 Bags or 2 lbs 8 oz Contac...

Page 17: ...tructions for detailed operation information LIGHTING INSTRUCTIONS A This appliance is equipped with an ignition device which au tomatically lights the pilot Do not try to light the pilot by hand use...

Page 18: ...ed mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used CAUTION Do not operate the appliance with glass panel remov...

Page 19: ...rature Ratings 0 50 C 32 122 F Radio Frequency 315 MHz NOTICE THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE RECEIVER IN OR NEAR METAL SEVERELY REDUCES THE SIGNAL RANGE NOTICE TU...

Page 20: ...on Display With the system in the OFF position press the THERMOSTAT key and the MODE key at the same time Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of t...

Page 21: ...sing the DOWN ARROW key once will reduce the flame height by one step until the flame is turned OFF The UP ARROW key will increase the flame height each time it is pressed If the UP ARROW key is press...

Page 22: ...displayed on the LCD screen of the Transmitter Figure 33 SMART Thermostat Operation The Smart Thermostat function adjusts the flame height in accor dance with the difference between the set point temp...

Page 23: ...off or adjust fan speed See Figures 25a and 36 A single beep will confirm reception of the command Figure 36 Fan Icon Figure 37 Fan Speed Control Activated Continuous Pilot Intermittent Pilot CPI IPI...

Page 24: ...sing the Insert Without a Remote Control Remove the decorative front and outer surround to access the module With the ON OFF rocker switch in the ON position press with SW1 button on the module The mo...

Page 25: ...ion Glass Cleaning It will be necessary to clean the glass periodically During start up condensation which is normal forms on the inside of the glass and causes lint dust and other airborne particles...

Page 26: ...o screws securing the bottom flange to the firebox See Figure 43 6 Hand bend the flange so that lays flat See Figure 43 7 Remove blower from appliance and disconnect the wires at the connectors and di...

Page 27: ...e the air box and set aside See Figure 47 Figure 47 16 Remove the 18 screws securing the blower access panel to the firebox and set aside Remove the blower access panel and set aside See Figure 48 Fig...

Page 28: ...34961 2 1015 Page 28 DECORATIVE FRONTS...

Page 29: ...be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number an...

Page 30: ...11 R10424 R10424 PILOT ASSEMBLY LPG 12 31246 28917 PILOT SHIELD 13 31195 31196 GLASS FRAME ASSEMBLY 14 28943 28943 AIR BOX 15 28848 28848 BLOWER ACCESS PANEL 16 31247 31247 BLOWER BRACKET 17 R11534 R...

Page 31: ...34961 2 1015 Page 31 20 19 18 17 16 15 14 21 22 23 24 7 6 8 12 11 10 4 3 2 1 13 5 25 26 EXPLODED VIEW...

Page 32: ...th this appli ance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for...

Page 33: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Page 34: ...Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be...

Page 35: ...34961 2 1015 Page 35 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 36: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Reviews: