Vent System Approvals

Figure 9 

shows the vent termination caps and systems approved 

for use with these models. Approved vent system terminations are 

labeled for identification. 3-inch diameter listed flexible aluminum 

or stainless steel gas vent is used for both the incoming combustion 

air and exhaust vent pipes. NO OTHER VENTING SYSTEMS OR 

COMPONENTS MAY BE USED. Detailed installation instructions 

are included with each vent termination kit and should be used in 

conjunction with this manual. See page 5 for approved venting 

kits.

Horizontal Venting

The vent system on this model 

CANNOT 

be terminated horizontally.

Vertical Venting

The inlet and exhaust vent pipes 

MUST 

be connected to the proper 

collars on the unit 

AND 

to the termination cap or the unit will not 

operate. 

See Figure 7.

 

WARNING

MAJOR U.S. BUILDING CODES SPECIFY MINIMUM 

CHIMNEY AND/OR VENT HEIGHT ABOVE THE ROOF 

TOP. THESE MINIMUM HEIGHTS ARE NECESSARY IN 

THE INTEREST OF SAFETY. SEE FIGURES 9 TO 11 FOR 

MINIMUM HEIGHTS, PROVIDED THE TERMINATION CAP IS 

AT LEAST 2-FEET FROM A VERTICAL WALL AND 2-FEET 

BELOW A HORIZONTAL OVERHANG.

NOTICE:

 

This also pertains to vertical vent systems installed on 

the outside of the building.

 

WARNING

THE EXHAUST PIPE MUST ONLY BE CONNECTED TO THE 

EXHAUST STARTING COLLAR OF THE UNIT AND TO THE 

EXHAUST COLLAR OF THE TERMINATION CAP.
THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE 

INLET AIR STARTING COLLAR OF THE UNIT AND TO THE 

INLET AIR COLLAR OF THE TERMINATION CAP. BOTH THE 

INLET VENT AND THE FLUE VENT MUST BE CONNECTED 

FROM THE INSERT TO THE VENT TERMINATION CAP.

NOTICE

The minimum vertical vent rise is 10 feet and the 

maximum vertical vent rise is 35 feet. These dimensions are 

measured from the starting collars of the unit to the end of the last 

section of vent pipe. 

See Figure 8.

NOTICE

The damper of the masonry chimney may need to be 

removed to allow installation of the flexible-vent pipe.

When installing into a zero clearance, factory built wood-burning 

fireplace, the use of the DVKI Round Vertical Termination Kit should 

allow you to mount the vent adaptor and cap to the exposed  round 

chimney pipe easily.

Connecting the Vent Pipe

 

CAUTION

Sharp edges. Always use gloves when installing.

Install the 3-inch flexible vent pipes down through the chimney.

Attach the pipe-to-cap adaptor to the termination cap and the top of 

the flexible vent pipe, then install the cap to the top of the chimney. 

Remove the vent slide plate assembly from the top of the insert. 

See Figure 8. 

Trim off excess venting then attach and secure 

the bottom ends of the flex pipes to the starting collars with the 

adjustable band clamps provided. Slide the gas insert into place, 

and position any excess flex vent pipe back up into the chimney. 

Begin installation of the insert into the fireplace opening. Align the 

vent slide plate assembly with the guides located on top of the 

insert. Work the insert inch by inch into the fireplace cavity as you 

pull forward on the vent slide plate assembly. Do not use excessive 

force on the vent slide plate. Once the vent slide plate is close to 

seating, install the bolt (provided in the Instruction Envelope pack) 

through the center hole of the insert top flange, and into the vent 

slide plate nut. Using a wrench tighten the bolt until the vent slide 

plate is seated forward completely. 

Positioning, Leveling, and Securing Insert

1.  Place the insert into position.

2.  Level the insert from side to side and front to back.

3.  If necessary, use the leveling bolts included in the instruction 

pack. Screw the legs into the nuts installed in the bottom of 

the insert. Turn legs in until insert is level. 

 

 

NOTICE:

 If desired, it is acceptable to attach metal strapping 

or brackets (not provided) from the fireplace cavity to the insert 

outer  jacket  to  secure  the  Fireplace  Insert  to  the  fireplace 

hearth or opening.

 

CAUTION

TO AVOID DOWNDRAFTS AND/OR COLD AIR PROBLEMS, 

IT IS RECOMMENDED TO SEAL OFF THE AREA BETWEEN 

THE TERMINATION CAP AND THE TOP OF THE SOLID-

FUEL CHIMNEY OPENING INTO WHICH THE VENT CAP 

HAS BEEN INSTALLED.

Figure 7

Figure 8

VENTING AND INSTALLATION

Summary of Contents for DXL30IN91N-2

Page 1: ...ch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you c...

Page 2: ...ts 1 2 3 4 6 7 8 5 BEFORE YOU START 1 Read the safety information on Pages 32 33 2 Install the wiring See page 18 3 Install the venting See pages 9 11 4 Install the fireplace See pages 9 11 5 Connect...

Page 3: ...14 BURNER COVER REMOVAL PLACEMENT 15 DECORATIVE MEDIA PLACEMENT 16 LIGHTING INSTRUCTIONS 17 IPI SYSTEM WIRING DIAGRAM 18 REMOTE CONTROL OPERATION INSTRUCTIONS 19 24 INSERT MAINTENANCE AND SERVICE 25...

Page 4: ...with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from theAmerican National Standards Institute Inc 11 West 42nd St New Yo...

Page 5: ...Model Description Used On DS3066BL 3 Sided 1 Piece Matte Black DXL30IN DS3566BL 3 Sided 1 Piece Matte Black DXL35IN REFLECTIVE LINERS Model Description Used On DVP30CKR Black 30 Inch DXL30IN DVP30CWR...

Page 6: ...irements Proper opening size of fireplace required for installation of the fireplace insert INSERT DIMENSIONS in inches DIMENSION DXL30IN DXL35IN A 20 1 8 24 1 16 B 29 3 8 33 3 8 C 18 5 8 21 3 4 D 15...

Page 7: ...m Face of Fireplace dimensions in inches Height Above Top of Insert dimensions in inches A 10 F 14 B 8 G 17 1 2 C 6 H 21 1 2 D 3 I 24 1 4 E 1 2 J 27 The minimum distance to the room ceiling from the T...

Page 8: ...size or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied pe...

Page 9: ...e the exposed grille area should be left open NOTICE Surround panel kits have been tested and approved to cover existing air circulation vents or grilles NOTICE Cutting of sheet metal parts of a firep...

Page 10: ...a zero clearance factory built wood burning fireplace the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily Con...

Page 11: ...34961 2 1015 Page 11 VENTING AND INSTALLATION Figure 9...

Page 12: ...n the flex venting and subsequently dripping out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having exterior portio...

Page 13: ...ssembly Figure 13 5 Repeat step 4 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of the clip while pulling injury may occur Ensure that the latch tool i...

Page 14: ...pull the latch out and up until it engages to the glass assembly Figure 16 5 Repeat step 4 through 5 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of...

Page 15: ...urner cover out from the back past the front of the unit Tilt the burner cover to the side and lift out See Figures 19 and 20 Set the burner cover aside Figure 19 Figure 20 Note Install firebox liners...

Page 16: ...2 3 Bag or 1lb 10 oz 1 Bag or 2 lbs DXL30IN LP Approximately 2 3 Bag or 1lb 10 oz 1 Bag or 2 lbs DXL35IN NAT 3 4 Bag or 1lb 8 oz 2 Bags or 2 lbs 8 oz DXL35IN LP Not Allowed 2 Bags or 2 lbs 8 oz Contac...

Page 17: ...tructions for detailed operation information LIGHTING INSTRUCTIONS A This appliance is equipped with an ignition device which au tomatically lights the pilot Do not try to light the pilot by hand use...

Page 18: ...ed mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used CAUTION Do not operate the appliance with glass panel remov...

Page 19: ...rature Ratings 0 50 C 32 122 F Radio Frequency 315 MHz NOTICE THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE RECEIVER IN OR NEAR METAL SEVERELY REDUCES THE SIGNAL RANGE NOTICE TU...

Page 20: ...on Display With the system in the OFF position press the THERMOSTAT key and the MODE key at the same time Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of t...

Page 21: ...sing the DOWN ARROW key once will reduce the flame height by one step until the flame is turned OFF The UP ARROW key will increase the flame height each time it is pressed If the UP ARROW key is press...

Page 22: ...displayed on the LCD screen of the Transmitter Figure 33 SMART Thermostat Operation The Smart Thermostat function adjusts the flame height in accor dance with the difference between the set point temp...

Page 23: ...off or adjust fan speed See Figures 25a and 36 A single beep will confirm reception of the command Figure 36 Fan Icon Figure 37 Fan Speed Control Activated Continuous Pilot Intermittent Pilot CPI IPI...

Page 24: ...sing the Insert Without a Remote Control Remove the decorative front and outer surround to access the module With the ON OFF rocker switch in the ON position press with SW1 button on the module The mo...

Page 25: ...ion Glass Cleaning It will be necessary to clean the glass periodically During start up condensation which is normal forms on the inside of the glass and causes lint dust and other airborne particles...

Page 26: ...o screws securing the bottom flange to the firebox See Figure 43 6 Hand bend the flange so that lays flat See Figure 43 7 Remove blower from appliance and disconnect the wires at the connectors and di...

Page 27: ...e the air box and set aside See Figure 47 Figure 47 16 Remove the 18 screws securing the blower access panel to the firebox and set aside Remove the blower access panel and set aside See Figure 48 Fig...

Page 28: ...34961 2 1015 Page 28 DECORATIVE FRONTS...

Page 29: ...be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number an...

Page 30: ...11 R10424 R10424 PILOT ASSEMBLY LPG 12 31246 28917 PILOT SHIELD 13 31195 31196 GLASS FRAME ASSEMBLY 14 28943 28943 AIR BOX 15 28848 28848 BLOWER ACCESS PANEL 16 31247 31247 BLOWER BRACKET 17 R11534 R...

Page 31: ...34961 2 1015 Page 31 20 19 18 17 16 15 14 21 22 23 24 7 6 8 12 11 10 4 3 2 1 13 5 25 26 EXPLODED VIEW...

Page 32: ...th this appli ance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for...

Page 33: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Page 34: ...Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be...

Page 35: ...34961 2 1015 Page 35 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 36: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Reviews: