31259-3-0114
Page 7
Figure 1
Notice
:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
SPECIFICATIONS
FIREPLACE DIMENSIONS
DVLT36 NAT
DVTT36 NAT
DVLT36 LP
DVTT36 LP
DVLT42 NAT
DVTT42NAT
DVLT42 LP
DVTT42LP
Input Btu/hr Maximum
40,000
40,000
50,000
50,000
Input Btu/hr Minimum
23,000
23,000
25,000
26,500
KWH (Maximum)
11.7
11.7
14.70
14.7
KWH (Minimum)
6.7
6.7
7.3
7.8
Orifice - Front
#43
1.35 mm
#39
#53
Orifice - Rear
#43
#55
#39
#53
Air Shutter Opening - Front
DVLT36 - 1/8"
DVTT36 - 3/8"
DVLT36 - 1/4"
DVTT36 - Wide Open
DVLT42 - 1/8"
DVTT42 - 3/8"
DVLT42 - Wide Open
DVTT42 - Wide Open
Air Shutter Opening - Rear
DVLT36 - 1/8"
DVTT36 - 3/8"
DVLT36 - 3/8"
DVTT36 - Wide Open
DVLT42 - 1/8"
DVTT42 - 3/8"
DVLT42 - 3/8"
DVTT42 - Wide Open
Height without standoff
39-1/4" (997mm)
39-1/4" (997mm)
45-1/4" (1,149mm)
45-1/4" (1,149mm)
Width
55" (1,397mm)
55" (1,397mm)
61" (1,549mm)
61" (1,549mm)
Depth
22" (559mm)
22" (559mm)
22" (559mm)
22" (559mm)
Gas Inlet Shutoff Valve
(Pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
C
A
D
▲
►
▼
◄
▲
▼
J
F
A
B
◄
►
◄
◄
▲
▼
H
K
▲
▼
▼
▲
►
►
E
▲
▼
DIMENSIONS
DVTT36/DVLT36 DVTT42/DVLT42
A
55
(1,397mm)
61
(1,549mm)
B
39-7/8
(1,012mm)
45-7/8
(1,165mm)
C
30-15/16
(785mm)
36-15/16
(938mm)
D
51-5/16
(1303mm)
57-5/16
(1,445mm)
E
39-5/16
(998mm)
45-5/16
(1,150mm)
F
22
(558mm)
22
(558mm)
H
6-3/4
(171mm)
6-3/4
(171mm)
J
27-1/2
(698mm)
30-1/2
(774mm)
K
15-1/4
(387mm)
15-1/4
(387mm)
TOP VIEW