JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
ACCENT LAMP LIGHT REPLACEMENT
Your Luxury Direct Vent Gas Fireplace comes equipped with
our "Accent Lamp." The light has been pre-wired and is
controlled from the
remote.
DVLT ACCENT LAMP LIGHT REPLACEMENT
If in the event the lamp or lens needs to be replaced, follow the
instructions below:
1. Unplug the remote from the junction box or disconnect all power
to the fireplace.
2. Remove the screen (if equipped) and remove the front panels.
3. Remove the glass frame assembly by unhooking the 8 spring
clips around the glass.
4. Remove about 1/4" of the media (beads) across the top of the
burner.
5. Remove the two screws on the sides of the burner cover.
6. Grasp the burner cover and lift up while slightly tipping the grate
forward.
See Figure 63.
7. The light bulbs are located underneath the media basket.
8. Pull the old bulb out and push the new bulb in.
IMPORTANT: Do not handle the lamp (bulb) with bare
fingers, protect with clean dry cloth.
9. Place the burner cover back in place by tipping it back into
place while lowering it down.
10. Make sure the glass media doesn't hold the burner cover up.
Move any beads out of the way if it does.
11. Re-attach the grate down with the two screws. Replace the
glass media over the burner.
NOTE: The lamp will pull straight out of the socket. Replace
with 35 Watt/120 Volt Halogen bulb. When re-installing, ensure
integrity of gasket seal.
MEDIA BASKET FILLED
WITH GLASS MEDIA (BEADS)
LIFT AND PULL BURNER COVER
FORWARD TO REMOVE
LAMP (BULB)
Figure 63 - Side view of burner
CAUTION
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRI-
CIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL,
CITY AND STATE BUILDING CODES. BEFORE MAKING THE
ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POW-
ER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN
INSTALLED, MUST BE ELECTRICALLY GROUNDED IN AC-
CORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF
LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE
ANSI/NFPA 70 (LATEST EDITION).
A factory installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
to the receptacle that is provided. Leave approximately 6" of wire
in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
▲
►
▼
◄
◄