31629-20-0320
Page 8
Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson
Duravent part numbers and pricing.
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers
DVVK-4FV
Vertical Flex Vent Kit 4" x 7"
DVVK-4VP
Direct-Vent Fireplace Vent Kit - Vertical,
Includes SD-991, SD-953, and SD-943
DVVK-4TP
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 8 to 11 inch wall thickness,
Includes SD-911, SD-985, SD-990 and SD-942
DVVK-4RP
Direct-Vent Fireplace Vent Kit for Rear Vent, 5
to 7 inch wall thickness, (standard thru-the-wall
venting) Includes SD-908, SD-985 and SD-942
DVVK-4RE
Direct-Vent Fireplace Vent Kit for Rear Vent,
Thru-the wall, 5 to 7 inch wall thickness,
(standard thru-the-wall venting) Includes SD-
908, SD985 and SD-942
DVVK-4TSP
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 5 to 7 inch wall thickness,
Includes SD-908, SD-985, SD-990 and SD-942
VIB6A
Vertical Inlet Baffle Kit for 6 5/8" diameter.
VIB7A
Vertical Inlet Baffle Kit for 7" diameter.
VENT SYSTEM IDENTIFICATION
The following vent systems are acceptable for use with the
DVD (32, 36, 42, 48) series fireplaces:
•
Simpson Duravent® GS 4” - 6 ⅝”
•
American Metal Products 4” - 6 ⅝”
•
Selkirk Direct-Temp® 4” - 6 ⅝”
•
MetalFab SureSeal® 4” - 6 ⅝”
SPECIAL VENT SYSTEMS
•
Security Secure Vent® 4” - 6 ⅝”
•
Excel DV 4” - 6 ⅝”
•
Empire Horizontal Round Termination Kit
DVVK-4RE, DVVK-
4REVS
Empire Flexvent Kits:
•
DVVK-4F, DVVK-4FV, DVVK-4FRE, DVVK-4FREVS
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NOTICE:
Some fireplaces cannot be vented out the rear of the fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to the
“Special Vent Systems” section in this manual to determine what
systems are acceptable.
Check all clearances and venting components. Identify if any
problems existing in the vent system. Use Figure 22, page 18 for
top venting or Figure 32, page 22 for rear venting to eliminate issues
after installation. Check pipe diameter on vent system and fireplace
to verify the size is the same.
NOTICE
: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
Figure 1
Summary of Contents for DVD32
Page 21: ...31629 20 0320 Page 21 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN ...
Page 41: ...31629 20 0320 Page 41 Figure 61 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES ...
Page 52: ...31629 20 0320 Page 52 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 53: ...31629 20 0320 Page 53 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 59: ...31629 20 0320 Page 59 DVD36FP 3 5 7 PARTS VIEW ...
Page 61: ...31629 20 0320 Page 61 DVD42FP 3 5 7 PARTS VIEW ...
Page 63: ...31629 20 0320 Page 63 DVD48FP 3 5 7 PARTS VIEW ...