31629-20-0320
Page 20
VENTING FIREPLACE - TOP (CONT’D)
Cutting the Hole
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 11" (280mm) high x 10" (254mm) wide with its center line
determined by the amount of vertical rise and horizontal run of the
termination.
See Figure 26.
When locating the hole it must be noted
that the bottom of the cap must be 12" (305mm) above the ground
level, and top of the cap must be no less than 18" (457mm) below a
combustible projection, and no closer than 9" (229mm) to any wall
running parallel to vent termination.
See Figure 27.
Figure 27
Figure 28
FIREPLACE
SERIES
HARD ELBOW DIMENSIONS
"A"
"B"
"C"
"D"
DVD32FP
41-1/2"
(1054 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
DVD36FP
41-1/2"
(1054 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
DVD42FP
43-1/2"
(1105 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
DVD48FP
43-1/2"
(1105 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
FIREPLACE
SERIES
FLEX PIPE 90 DEGREE BEND
"A"
"B"
"C"
"D"
DVD32FP
43"
(1092 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
DVD36FP
43"
(1092 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
DVD42FP
45"
(1143 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
DVD48FP
45"
(1143 mm)
4-1/2"
(114 mm)
6-1/2"
(165 mm)
9 1/8"
(232 mm)
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH
THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW OFF TOP OF FIREPLACE
SEE FIGURE 22 ON PAGE 18 FOR PERMISSIBLE “H” AND
“V” DIMENSIONS.
Figure 26
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Summary of Contents for DVD32
Page 21: ...31629 20 0320 Page 21 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN ...
Page 41: ...31629 20 0320 Page 41 Figure 61 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES ...
Page 52: ...31629 20 0320 Page 52 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 53: ...31629 20 0320 Page 53 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 59: ...31629 20 0320 Page 59 DVD36FP 3 5 7 PARTS VIEW ...
Page 61: ...31629 20 0320 Page 61 DVD42FP 3 5 7 PARTS VIEW ...
Page 63: ...31629 20 0320 Page 63 DVD48FP 3 5 7 PARTS VIEW ...