31629-20-0320
Page 50
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
TO TURN OFF GAS TO FIREPLACE
GAS SHUT-OFF VALVE
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Remove front surround panel assembly or bottom louver if
included.
4. Turn gas shut-off counterclockwise
to “On” position.
5. Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow “B” in
the safety information above on this page. If you do not smell
gas, go to the next step.
6. Turn ON electric power to the appliance.
7. Find pilot - Follow metal tube from gas control. The pilot is
behind the burner on the right side.
8. Turn main flame to on. If the pilot does not light within 60
seconds, stop and go to Step 5.
9. Refer to remote control instructions for detailed information,
control features, and operation. Note: There is a CPI/IPI
switch that allows for a continuous standing pilot mode or an
intermittent pilot mode. See appliance manual for location
of this switch. If the pilot or burner does not stay lit (in the
standing pilot mode), stop and immediately call a qualified
service technician or gas supplier.
10. If the burner or pilot does not operate properly after several
tries, turn the gas shut-off clockwise
to “OFF” and
call your service technician or gas supplier.
11. Replace the front surround assembly or close bottom louver
assembly.
12. Operation of the gas valve is controlled by a manual on/
off switch or a hand held remote control. Refer to remote
instructions for detailed operation information.
INTERMITTENT PILOT LIGHTING INSTRUCTIONS (FP7 SERIES)
A. This appliance has a pilot which can be lighted with the
manual on/off switch, a remote control, or by switching the
receiver switch to the “ON” position. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical
switch. Do not use any phone in your building. Immediately
call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions. If you can not reach your gas
supplier, call the fire department.
C. Use only the remote control or manual remote receiver
switch to operate the gas valve. Never use tools. If valve
does not operate, don’t try to repair it, call a qualified ser
-
vice technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
1. Turn off all electric power to the appliance if service is to be
performed (if applicable).
2. Gain access to control compartment. Remove surround
panel assembly if necessary.
3. Locate On/Off gas shut-off and turn clockwise to
“OFF”. Do not force.
4. Close bottom louver assembly, if included.
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life
Summary of Contents for DVD32
Page 21: ...31629 20 0320 Page 21 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN ...
Page 41: ...31629 20 0320 Page 41 Figure 61 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES ...
Page 52: ...31629 20 0320 Page 52 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 53: ...31629 20 0320 Page 53 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 59: ...31629 20 0320 Page 59 DVD36FP 3 5 7 PARTS VIEW ...
Page 61: ...31629 20 0320 Page 61 DVD42FP 3 5 7 PARTS VIEW ...
Page 63: ...31629 20 0320 Page 63 DVD48FP 3 5 7 PARTS VIEW ...