31629-20-0320
Page 11
Figure 7
NOTICE:
Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not exceed 20 feet
with a minimum vertical run of 8 feet. See details in Venting Section.
When you install your Direct Vent Fireplace in Room divider or Flat on wall corner positions, a minimum of six inches clearance must be
maintained from the perpendicular wall and the front edge of the appliance.
LOCATING FIREPLACE