31629-20-0320
Page 7
DVD32
DVD36
DVD42
DVD48
Input BTU/Hr Maximum
18000 (NAT, LP)
20,000 (NAT, LP)
25,000 (NAT, LP)
28,000 (NAT, LP)
Input BTU/Hr Minimum (millivolt only)
14,000 (NAT, LP)
14,000 (NAT)
16,500 (LP)
18,000 (NAT)
19,500 (LP)
20,000 (NAT)
22,000 (LP)
KWH (Maximum)
5.3
5.9
7.3
8.2
KWH (Minimum)
4.1
4.1
5.3
5.9
Orifice Natural
#46 (.081”) P254
2.10mm P288
#42 (.0935”) P286
#39 (.0995”) P285
Orifice Propane
#56 (.0465”) P287
#55 (.052”) P182
1.45mm P208
#52 P185
Air Shutter Opening Natural
1/16” (1.6mm)
1/16” (1.6mm)
3/16”(4.8mm)
1/8” (3.2mm)
Air Shutter Opening Propane
1/4” (6.3mm)
5/16” (7.9mm)
5/16” (7.9mm)
5/16” (7.9mm)
PROPANE
Height without standoff
32 3/4” (832mm)
32 3/4” (832mm)
34 3/4” (883mm)
34 3/4” (883mm)
Width
34” (864mm)
37” (940mm)
43” (1092mm)
49” (1245mm)
Depth
16 3/8” (416mm)
16 3/8” (416mm)
16 3/8” (416mm)
16 3/8” (416mm)
Gas Inlet Shutoff Valve (Pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
NOTICE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
GAS CONVERSION KITS
Models
DVD32FP3
DVD32FP7
DVD36FP3
DVD36FP7
DVD42FP3
DVD42FP7
DVD48FP3
DVD48FP7
NAT to LP
18456
32880
18442
32882
18814
31760
18815
31762
LP to NAT
18816
32881
18817
31759
18818
31761
18819
31763
Remote Control Options & Accessories
Description
Models Used On
FRBC
Millivolt Battery Remote ON/OFF
DVD(32,36,42,48)FP(3,7)
FRBTC
Millivolt Battery Remote Thermostat
DVD(32,36,42,48)FP(3,7)
FREC
Direct Ignition/Millivolt 120V ON/OFF
Remote
DVD(32,36,42,48)FP(3,5)
TMW
Millivolt Wireless Wall Thermostat
DVD(32,36,42,48)FP(3,7)
TRW
Millivolt Reed Switch Wall Thermostat
DVD(32,36,42,48)FP(3,7)
FWS-1
Direct Ignition/Millivolt Wall Switch
DVD(32,36,42,48)FP(3,5,7)
Venting Options
Description
DVVK-4TSP
Top vent kit (horizontal) - 4½" to 6" (114.3 mm to 152 mm) wall thickness
DVVK-4TP
Top vent kit (horizontal) - 8" to 12" (203 mm to 305 mm) wall thickness
DVVK-4RP
Rear vent kit (horizontal) - 5" to 7" (127 mm to 178 mm) wall thickness
DVVK-4VP
Vertical vent kit
DVVK-4F
Horizontal flex vent kit (4' FLEX)
DVVK-4RE
Horizontal round termination (wall thickness up to 13
3
/
4
”)
DV822
Vinyl siding kit for DVVK-4RE
FIREPLACE BARRIER SCREENS
Screen Model
Description
Fireplace Models Used On
DVFB32SBL
Fireplace Barrier Screen, Matte Black
DVD32FP
DVFB36SBL
Fireplace Barrier Screen, Matte Black
DVD36FP
DVFB42TBL
Fireplace Barrier Screen, Matte Black
DVD42FP
DVFB48TBL
Fireplace Barrier Screen, Matte Black
DVD48FP
NOTICE:
A firescreen is required for operation of the appliance, but are sold separately. Follow the instructions that come with your fire
-
screen for proper installation.
SPECIFICATIONS
Summary of Contents for DVD32
Page 21: ...31629 20 0320 Page 21 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN ...
Page 41: ...31629 20 0320 Page 41 Figure 61 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES ...
Page 52: ...31629 20 0320 Page 52 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 53: ...31629 20 0320 Page 53 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES ...
Page 59: ...31629 20 0320 Page 59 DVD36FP 3 5 7 PARTS VIEW ...
Page 61: ...31629 20 0320 Page 61 DVD42FP 3 5 7 PARTS VIEW ...
Page 63: ...31629 20 0320 Page 63 DVD48FP 3 5 7 PARTS VIEW ...