41521-2-0520
Page 8
SPECIFICATIONS
Model Number
DVCT40NAT
DVCT40LP
Input BTU/Hr Maximum (w/ both burners on)
60,500
55,000
Input BTU/Hr Minimum (w/ both burners on)
40,000
43,000
Input BTU/Hr Minimum (front burner on only)
16,500
26,000
KWH (Maximum)
17.73
16.12
KWH (Minimum)
11.73
12.60
Orifice - Front
#35
#52
Orifice - Rear
#37
1.55 mm
Air Shutter Opening Front
Full Closed
Full Opened
Air Shutter Opening Rear
Full Closed
Full Opened
Height without standoff (inches)
47-1/2
47-1/2
Width (inches)
57-1/4
57-1/4
Depth (inches)
24-3/16
24-3/16
Gas Inlet Shutoff Valve (pipe)
1/2 NPT
1/2 NPT
NOTE:
Air shutter is at factory-minimum settings. Some vent configurations may require minor air shutter adjustments for optimum performance.
GAS SUPPLY PRESSURES (Inches Water Column)
Gas Type
Maximum
Minimum
Manifold
Natural
14
4.5
3.5
Propane
14
10.8
10
VENTING
LIGHT BULB REPLACEMENT
5 x 8 Direct Vent System
35w Clear Halogen, Bi-Pin 6.35mm base,120vac, UL
ACCESSORIES
The following accessory parts can be obtained from your Empire Comfort Systems dealer. For additional information beyond what your dealer can furnish,
contact Empire Comfort Systems Inc., 918 Freeburg Ave., Belleville, Illinois 62220-2623.
Model Number
ACCESSORIES
Description
DFF40FPD
Decorative Front, Forged Iron Frame, Distressed Pewter
DFF40RPD
Decorative Arch Insert, Forged Iron, Distressed Pewter
DFF40CPD
Decorative Rectangle Insert, Forged Iron, Distressed Pewter (Requires DFF40FPD)
DCA1ABL
Andirons, Black
Model Number
CONVERSION KITS
Description
40636
Conversion Kit, IP System Natural to Propane Gas
40637
Conversion Kit, IP System Propane to Natural Gas
Model Number
OUTDOOR KIT
Description
DFED409SS
Frame, Stainless Steel
Model Number
LOG SETS
Description
LS40STB
Log Set for TruFlame Insert, Fiber - Traditional - Charred
Model Number
LINER KITS
DVP40PS...
A liner is required. Contact your Empire Comfort Systems Dealer for available liners.
NOTE:
A liner kit and log set must be purchased and installed in order to operate the unit. The liner must be installed before installing the logs.