41521-2-0520
Page 10
Mantel Chart
COMBUSTIBLES
ALLOWED
WALL
STUD
FIREBOX FACE
72” MINIMUM
(CEILING TO FLOOR)
CEILING
FLOOR
OPENING OF
FIREPLACE
35”
MIN.
24”
MIN.
14”
MIN.
10”
A
B
C
D
E
F
WALL
FACING
Index
Letter
DISTANCE FROM
WALL FACING
DISTANCE FROM
TOP OF OPENING
Dimensions (In Inches)
A
2
14
B
4
15-5/8
C
6
17-5/16
D
8
19
E
10
20-5/8
F
12
24
Figure 4
Clearances
Clearance from top opening of fireplace to ceiling is 35
inches.
Clearance from opening to adjacent sidewall is 9
inches
.
9” (228 mm)
TO FIREPLACE
OPENING
35” (889mm)
TO FIREPLACE
OPENING
Figure 5
CLEARANCES
CLEARANCE TO COMBUSTIBLES
Dimension (In Inches)
Back
N/A
Side
3
Floor
0
Top of Unit
24
Top Framing Edge
0
FINISHED WALL
(COMBUSTIBLE)
NONCOMBUSTIBLE
BOARD INSTALLED
OVER APPLIANCE
SEE MANTEL CHART
FOR MAXIMUM
MANTEL DEPTH
FRAMING HEADER
FINISHED WITH
NONCOMBUSTIBLE
MATERIAL AS
DESIRED
REFER TO
MANTEL CHART
BARRIER SCREEN
AND GLASS FRONT
NAILING
FLANGES
Figure 2
NOTICE:
Use only non-combustible materials to finish the face of
the fireplace.
9
PERPENDICULAR
SIDE WALL
3
MAX.
45
o
3
FRONT
FACE
(SIDE
Figure 3