41521-2-0520
Page 22
SPECIAL VENT SYSTEMS
Figure 32
GENERIC MODEL SHOWN
VENT SYSTEM IDENTIFICATION
FLASHING
STORM
COLLAR
VERTICAL
TERMINATION
(THREE 90°
ELBOWS MAX)
WALL THIMBLE
HORIZONTAL TERMINATION
(THREE 90° ELBOWS MAX)
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING
FIRE STOP
WALL STRAP
PIPE LENGTH
WALL THIMBLE SPACER
(DVCT36 ONLY)
SPECIAL DV VENT KITS
Available From Empire Comfort Systems, Inc. Dealers.
DVVK-5RP
Direct-Vent Fireplace Vent Kit for Rear Vent, 6
to 12 inch wall thickness, Includes 58DVA-06,
58DVA-WT, and 58DVAHC
DVVK-5TP
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 4 to 6 inch wall thickness,
Includes 58DVA-E90, 58DVA-HC, 58DVA-06,
and 58DVA-WT
DVVK-5VP
Direct Vent Fireplace Vent Kit - Vertical,
Includes 58DVA-VCH, 58DVA-SC, and
58DVA-F6
DVVK-5TS Top Vent Kit (Horizontal) - 4½" to 6" wall
thickness (114.3 mm to 152 mm)
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system.
NOTICE:
These fireplaces cannot be vented out the rear.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to the
“Special Vent Systems” section below to determine what systems
are acceptable.
Check all clearances and venting components. Identify if any
problems existing in the vent system.
NOTICE:
All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The inner
flue joints do not require any sealant.
•
Simpson Duravent ® GS 5 inch x 8 inch
•
Selkirk Direct-Temp ® 5 inch x 8 inch
•
Security Secure Vent ® 5 inch x 8 inch
•
Excel DV Venting 5 inch x 8 inch
•
Metal Fab Sure Seal ® 5 inch x 8 inch
– Adapter is required to use this vent
Contact Metal Fab
The following vent systems are acceptable for use: