GAS CONVERSION INSTRUCTIONS

DIRECT-VENT GAS FIREPLACE

 

WARNING

This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other 

qualified  agency¹)*  in  accordance  with  the  manufacturer’s  instructions  and  all  codes  and 

requirements of the authority having jurisdiction. Failure to follow instructions could result 

in serious injury or property damage. The qualified agency performing this work assumes 

responsibility for this conversion. 

1

 National Fuel Gas Code Z223.1 (Latest Edition) 

*The term “qualified agency” means any individual, firm, corporation or company which either 

in person or through a representative is engaged in and is responsible for (a) the installation 

of  gas  piping  or  (b)  the  connection,  installation  repair,  or  servicing  of  equipment,  who  is 

experienced in such work, familiar with all precautions required, and has complied with all the 

requirements of the authority having jurisdiction. 

CHECK THE SAFETY SHUTDOWN PERFORMANCE

 

WARNING

Perform the safety shutdown test any time work is done on a gas system to avoid the possibility 

of fire or explosion with property damage, personal injury or loss of life.

CHECK SAFETY SHUTDOWN SYSTEM

Intermittent Pilot System

1.  Switch main switch to “OFF” position. Main burner and pilot should go off.

2.  Pilot gas flow should stop within 30 seconds. 

3.  Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.

PARTS LIST

Part 

Description

Conversion Kit 

32880

Conversion Kit 

32882

Conversion Kit 

31760

Conversion Kit 

31762

Quantity 

Supplied

Pilot Orifice

R10426

R10426

R10426

R10426

1

Main Burner 

Orifice

P287

P182

P208

P258

1

SIT Gas Valve 

Conversion Kit

R11169

R11169

R11169

R11169

1

Gas Conversion 

Label

2139

2139

2139

2139

1

Tools Needed: Standard Screwdriver, 1/4" Hex Driver, 5/16" Hex Driver, 3/8" and 7/16" Wrenches

CONVERSION KITS

Model 

Part No.

Model

Part No.

DV(D,CD)32FP7

 32880

DV(D,CD)42FP7

31760

DV(D,CD)36FP7

32882

DVD48FP7

31762

FOR CONVERSION TO

 PROPANE GAS

Summary of Contents for DVCD32FP7

Page 1: ...ith all the requirements of the authority having jurisdiction CHECK THE SAFETY SHUTDOWN PERFORMANCE WARNING Perform the safety shutdown test any time work is done on a gas system to avoid the possibility of fire or explosion with property damage personal injury or loss of life CHECK SAFETY SHUTDOWN SYSTEM Intermittent Pilot System 1 Switch main switch to OFF position Main burner and pilot should g...

Page 2: ...y Push downward to snap in place 16 Convert the gas valve as instructed in S I T Propane Gas Valve Conversion Kit 17 Align burner assembly with the air shutter as you place burner assembly into the original position in firebox 18 Adjust air shutter setting to FULL Open on all models 19 Attach burner assembly with four 4 10 x 1 2 screws from Step 8 20 Attach rear log support with 2 10 x 1 2 screws ...

Page 3: ...URITÉ AVERTISSEMENT Exécuter un essai d arrêt de sécurité après chaque intervention sur le système de gaz afin d éviter les risques d incendie ou d explosion causant des dégâts matériels des blessures corporelles voir la perte de vie VÉRIFIER LE SYSTÈME D ARRÊT DE SÉCURITÉ Système de veilleuse intermittente 1 Placer l interrupteur principal en position OFF Arrêt Le brûleur principal et la veilleus...

Page 4: ...leuse Pousser vers l avant pour l enclencher 16 Convertir la soupape de gaz tel que mentionné dans le Nécessaire de conversion de soupape au gaz propane S I T 17 Aligner l ensemble de brûleur avec l obturateur d air lors de la mise en place du brûleur dans sa position d origine dans la chambre de combustion 18 Ajuster le réglage de l obturateur d air COMPLÈTEMENT Ouvert sur tous les modèles 19 Fix...