41380-0-0120
Page 57
The OWNER should carefully read and follow these operating
instructions at all times. Remove the barrier to view the gas
controls for the fireplace insert.
The electronic control valve system includes the ability to switch
the pilot from a standing pilot mode to an intermittent pilot mode.
•
IPI Mode
- In the Intermittent Pilot mode, when the unit
is turned ON, it will cause spark to the pilot, light the
pilot, then allow the burner to light. When the unit is
turned to OFF, both the burner and pilot will be OFF.
•
CPI Mode
- In the “Pilot On Demand” mode, the pilot
remains ON continuously even when the burner is
turned OFF. The pilot will shut off after 7 days if there is
no activity or call for heat.
NOTICE
: A small toggle switch is located on the front of the
module tray that is used to switch from IPI (left position) to the
CPI (right position).
See Figure G.
When the unit is turned to ON, the electrical current will energize
a spark to the pilot igniter. Once the pilot sensor heats up (after a
few seconds), the valve will be energized, allowing gas to flow to
the burner.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for
Intermittent Pilot controls found in this manual, and on labels
found in the control compartment located in the lower cavity
of the appliance.
2. During the operating season (or in power outage periods),
it is recommended that the pilot remain in the CPI (standing
pilot mode) to reduce cold start issues, and/or conserve
battery backup power during a power outage.
NOTICE
:
The gas control has a manual HI/LO flame adjustment
knob (regulator) that allows you to increase or decrease the
height of the burner flame.
See Figure G.
Rotate the HI/LO
knob counterclockwise to
“
HI
”
to increase the flame height, and
clockwise to
“
LO
”
to decrease the flame height.
OPTIONAL REMOTE CONTROLS
Optional remote controls are available for use with this appliance.
Follow the instructions included with the remote control for
programming and other operational information.
Figure G
INTERMITTENT PILOT (DVC(20,26,28)IN7 MODELS)
OPERATING INSTRUCTIONS