41380-0-0120
Page 38
(GND)
PILOT
CPI/IPI
SWITCH
GAS CONTROL
VALVE
ELECTRONIC
CONTROL MODULE
BATTERY HOLDER
BATTERY
BACK-UP
RED
BLACK
RED
BLACK
GREEN
WHITE
WHITE
BLUE
BLUE
WHITE
ORANGE
GREEN
YELLOW
WHITE
ORANGE
AC/DC
POWER ADAPTOR
REMOTE RECEIVER
(OPTIONAL)
(
(
(
+ ON
REMOTE
- OFF
BLACK
BLAC
K
ON/OFF
SWITCH
OR
IPI ELECTRONIC SYSTEM WIRING DIAGRAM
If any of the original wire as supplied with this unit must be
replaced, it must be replaced with equivalent gauge and
temperature rated wire.
This appliance is only for use with the type of gas indicated
on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not
prohibited by local codes. This appliance is not convertible for
use with other gases, unless a certified kit is used.
REMOTE RECEIVER
If a remote receiver is installed in the insert, a receiver shield
should be placed over the receiver. The receiver shield is
included in the instruction packet. The shield must be hand
formed as shown.
See Figure 33.
Remote Receiver Shield
Remote Receiver (Optional)
Figure 33
CAUTION
Do not operate the appliance with panel(s) removed,
cracked or broken. Replacement of the panel(s) should be
done by a licensed or qualified service person.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from
this plug. The AC/DC adapter, if used, has a 2-prong plug
which does not require an additional ground.
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation.