41380-0-0120
Page 20
ALTERNATE ON/OFF SWITCH INSTALLATION
WIRING THE FIREPLACE
CAUTION
Disconnect remote controls if you are absent for extended
time periods. This will prevent accidental fireplace operation.
Installation of Alternate Surround Panel ON/OFF Switch
An ON/OFF switch and wire assembly is provided. They are
included in the instruction packet.
Do not cut wire or insulation on metal edges.
Contemporary Surrounds
1. Find the coiled low voltage wire assembly and ON/OFF
switch located in the instruction packet.
2.
Millivolt Valve
- Attach the flag terminal ends to the
“
TH/TP
”
and
“
TH
”
terminals on the front terminal block of the
gas valve.
See Figure 17.
“
IP
”
Valve
- Locate the two 5-1/2
-inch
long black wires
connected to the ON/OFF switch. Disconnect these two
black wires at the green and white wire connections. Attach
the flag terminals (the low voltage wire assembly found in the
Instruction Packet) to the green and white wire connections.
See Figures 18 and 19.
3. Run the low voltage alternate switch wires to the right or left
surround panel. Use the top knockout location. Then secure
the wires with wire clips provided.
See Figure 16.
WIRING FROM
GAS VALVE
ON/OFF
SWITCH
ASSEMBLY
BLOWER
CORD
Figure 16
Insert ON/OFF switch into side panel then attach wire
assembly from valve terminals.
4. Remove the desired switch knockout on the side surround
panel, then install the ON/OFF switch.
5. Connect the low voltage wires from the gas valve to the
ON/OFF switch.
a. For millivolt valve connections,
see Figure 17.
b. For IP valve connections, locate the green and white wires
from the control module, then connect the switch wire flag
terminals to the green and white wire terminals.
See Figures
18 and 19.
Figure 17
OF
F
GREEN WIRES
WHITE WIRES
REMOVE BLACK SWITCH WIRES
Figure 18
OF
F
ATTACH EXTENSION SWITCH WIRES
Figure 19
6. Attach the surround assembly to the insert.
See Figure 15
on page 19 and refer to the installation instructions supplied
with the surround.