60
GB
GB
6. INSTALLATION OF THE INDOOR UNIT
6.1 Outdoor unit installation
- Install the anti –vibration rubber pads under the Outdoor unit (acces-
sory provided separately) and place the unit on a raised part of at
least 10 cm as shown in Fig. A.
- Make sure about the stability and the levelling of the surface where
unit is placed.
- When several Outdoor units have to be installed, it is essential to
assure distances between the units which do not restrict air circula-
tion to the single units and to make maintenance operations easier
(Fig. B)
- In case of under roof installation or similar, please follow the indica-
tions shown in fig. C
A
A
Fig. B
A = min 60 cm
Fig. C
min 400 mm
min 400 mm
A
A = 10 cm
Fig. A
A = 10 cm
Nota:
Fixing brackets are accessories supplied separately
6.2 Outdoor unit condensation drain pipe
The outdoor unit is provided with a hole in the lower part of the frame,
which through a conical connection (supplied), drains the condensation
water.
- Insert the gasket on the fitting
- Insert the fitting on the bottom of the outdoor unit
- Rotate the fitting 90 ° until you hear the click
- The rubber union attachment is a push-fit.
- The condensation drain-pipeline should be slightly tilted so as to
favour the natural outflow.
- It is advisable to use a plastic pipe sufficiently rigid to avoid its being
flattened.
Attention!
Place the condensation water outlet so that no damage may be caused
to people or things.
It is advisable to be able to visually check the outlet drain at the end of
the piping, or alternatively insert a transparent section in the tubing
itself when it flows into an outlet which cannot be inspected.
Installation and maintenance activities on the air conditioners can
be done by personnel and companies holding appropriate certi-
ficate according to the Regulation EU 2015/2067 which provides
the minimum requirements of the companies and of the personnel
about fixed units of refrigeration, air condition and heating pumps
which contain some fluorinated greenhouse gases, according to
the Regulation EU 517/2014 of the European Parliament and of the
Council.
- Installation must be performed by qualified and authorized personnel.
- Do not attempt to install the unit by yourself.
- For any repairs, contact the service centre.
- Repairs of an electrical nature must be performed by qualified
electricians.
- Improper operations may cause serious harm to the user.
- You can find a list of service centres at the website
www.emmeti.com
The right installation of the air conditioner assure its efficiency
Therefore we invite you to follow the instructions carefully about positio-
ning, installation, connexions and test listed in these manuals.
CAUTION
Danger cut: use of gloves.
If the conditions are met Arrange for work at height.
Gasket
Hole at the bottom of the
outdoor unit
Drainage joint
Gasket
Summary of Contents for X-REVO-0919E
Page 46: ...46 IT IT 1 DESCRIZIONE DEI COMPONENTI IT IT...
Page 48: ......
Page 88: ...GB GB 88 EEV EEV EEV EEV Electric diagrams QUADRIAL 36 kBtu X REVO 3619QE 10 ELECTRIC DIAGRAM...
Page 93: ......
Page 94: ......
Page 95: ......